My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2802 WETMORE AVE TRINITY LUTHERAN CHURCH 2018-01-02 MF Import
>
Address Records
>
WETMORE AVE
>
2802
>
TRINITY LUTHERAN CHURCH
>
2802 WETMORE AVE TRINITY LUTHERAN CHURCH 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2022 7:49:00 AM
Creation date
3/9/2017 1:12:57 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2802
Tenant Name
TRINITY LUTHERAN CHURCH
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
202
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Info (Project Address Trinity Luther. College <br />2802 Wetmore Avo. <br />Everett, WA 98201 <br />Name: ROOGERS ELECTRIC <br />Address: PO Box 1152 Everett WA 98206 <br />Phone: 425-252-21D7 <br />Reese May 2W5 <br />11/5/2007 <br />T3fc1(I-0a5 <br />Project Description ❑ New Builaing ❑ Addition ❑Q Alteration ❑Plans Included <br />Refer to WSEC Section 1513 for controls and commissioning requirements. <br />Q Prescriptive Q Lighting Power Allowance Q Systems Analysis <br />Compliance Option <br />(Sec Qualification Checklist (over). Indicate Prescriptive 8 LPA spaces Dearly on plans. <br />Alteration Exceptions ❑ No changes are being made to the lighting <br />;check appropriate box - sec. 1132.3) 1 ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not c <br />Maximum Allowed Liehtine Wattaee (Interior) <br />-ocmion Allowed <br />'Boorlroom no.) Occupancy Description Watts per fe ^ Area in fe Allowed x Area <br />LOWER LEVEL SCHOOL BUILDING 1.35 5480.0 7398. <br />FIRST FLOOR SCHOOL BUILDING 1.35 13939.0 18617. <br />firm FLOOR SCHOOL BUILDING 1.35 10238.0 13821. <br />,FOURTH FLOOR SCHOOL BUILDING 1.35 10238.0 13821. <br />" From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Walls 53858. <br />Notes: <br />1. Use manufacturers listed maximum input wattage. For hard -wired ballasts only, <br />Die default table in the NREC Technical Reference Manual may also be used <br />2. Include exit lights unless less than 5 watts per fixture. <br />Prop OSed Lijjhti11(r Wattage (Interior) 3. List all fixtures. For exempt lighting, not exception and leave Watts/Fixture blank. <br />Location <br />(floor/room no.) <br />Fixture Description <br />Number of <br />Fixtures <br />Watts/ <br />Fixture <br />Watts <br />Proposed <br />FIRST FLOOR <br />A- 2'X4' RECESSED FLUORESCENT 3-321CTB <br />32 <br />96.0 <br />3072.0 <br />LOWER/FIRST <br />H- 2'X4' RECESSED FLUORESCENT 2-32WA <br />40 <br />64.0 <br />2560.0 <br />FIRST FLOOR <br />CP- DECORATIVE FLUORESCENT PENDANT 1-42W <br />24 <br />42.0 <br />1008.0 <br />LOWER/FIRST <br />D- 2'X4' RECESSED FLUORESCENT 3-32WO <br />15 <br />96.0 <br />1440.0 <br />THIRD/FVaMTH <br />F- 2'X2-' DIRECT/NNIRECT FLUORESCENT 2-40WTT5 <br />40 <br />80.0 <br />3200.0 <br />FIRST/THIRD/ <br />FORTH <br />G- 1'X4' SURFACE FLUORESCENT 2-32WB <br />18 <br />64.0 <br />1152.0 <br />FIRST/THIRD/ <br />FORTH <br />H- 2'X4' DIRECT/INDIRECT FLUORESCENT 3-32WTO <br />128 <br />96.0 <br />12288.0 <br />THIRD/FOURTH <br />HI- 21X2' DIRECT/INDIRECT FLUORESCENT 2-404I175 <br />14 <br />80.0 <br />1120.0 <br />FIRST/THIRD/ <br />FORTH <br />J- B" RECESSED FLUORESCENT DOWNLIGHT 1-32W <br />74 <br />32.0 <br />2368.0 <br />FIRST FLOOR <br />4' FLUORESCENT PENNANT 1-54W BHO <br />48 <br />54.0 <br />2592.0 <br />FIRST FLUOR <br />LVB- TRACK LIGHTING 5014T11116 <br />18 <br />50.0 <br />900.0 <br />FIRST/THIRD/ <br />FORTH <br />NI- 6" FLUORESCENT WALL HASHER 1-32W <br />41 <br />32.0 <br />1312.0 <br />FOURTH FLOOR <br />N- SUSPENDED DIRECT/INDIRECT FLUOR. 2-32W O <br />26 <br />64.0 <br />1664.0 <br />FOURTH FLOOR <br />Nl- SUSPENDED DIRECT/INDIRECT FLUOR. 2-32WTO <br />18 <br />64.0 <br />1152.0 <br />THIRD/FOURTH <br />P- SUSPENDED DIRECT/INDIRECT FLUOR. 1-26WT5 <br />15 <br />28.0 <br />420.0 <br />FIRST FLOOR <br />O- L40W VOLTAGE PENDANT 1-50WMR16 <br />19 <br />50.0 <br />950.0 <br />LOWER LEVEL <br />R- FLUORESCENT STRIP 2-32WTB <br />33 <br />64.0 <br />2112.0 <br />FOURTH FLOOR <br />S- INCANDESCENT SCONCE 1-50MIRIS <br />5 <br />$0.0 <br />250.0 <br />FOURTH FLOOR <br />T- INSCIANDESCENT WALL WASHER 1-50W 16 <br />91 <br />50.0 <br />450.0 <br />Total Proposed Watts may not exceed I otal Allowed Watts For Interior I Otal Proposea Watts) 40010.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.