My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3002 WETMORE AVE 2018-01-02 MF Import
>
Address Records
>
WETMORE AVE
>
3002
>
3002 WETMORE AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2022 2:41:22 PM
Creation date
3/9/2017 1:33:27 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3002
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
586
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTRUCTIONS: ORIGINATE MESSAGE ON WHITL COPY AND KELP GREEN COPY FOR <br />FUTURE REFERENCE. RECIPIENT REPLY ON WHITE COPY AND RETURN i'.i( prinhrn, inc <br />TO ORIGINATOR AFTER REMOVING YELLOW COPY FOR REFCRENCE. <br />TO :;ayor Anderson <br />FROM hill-- E Collins and L. J. Dougherty <br />GATE ?..ay 2, 1969. L ,� 00 <br />SUBJECT Inspection of the City Nall. CITY OF EVERETT, EVERETT. WASHINGTON <br />An. inspection was made of the City Hall on April 30, 1969 by the Fire <br />Mar and the Electrical Inspector. The following is the result of that <br />inspccticn. <br />1. ;'e recom,:end that all holes in ceilings and walls be scaled up. This <br />corditicn oxists in nearly every room in the basement as well as other <br />roGnz <br />2. All of the lights in the stairway are of an old type that .rust have a <br />cover over the globe. These lights should also be on the emergency circuit. <br />3. All exit lights should be put back in service. <br />11. A fire escape should be installed for the 2nd and 3rd floors. <br />5. The doors should be put back on the opening at the top of the stairs <br />on the 2rd floor. <br />6. There are several walls in the basement trade of wood which need to be <br />replaced with onr hour fire resistive construction. <br />7. The electrical distribution system needs to be checked over. We found <br />a few circuits that were over fused and many that were overloaded. 'riith <br />the exception of one or two offices, all need more cutlets. We found <br />extcndicn cords laying on the floor where people could walk on them as well <br />as trip over them. <br />3. There are several places where junction box covers must be replaced. <br />9. The Las is still turned on to the old gas stove in the engineers room <br />in the basement. If this stove is not in use the pas should be shut off <br />to it. <br />10. The stairway door in the basement needs an automatic closure installed <br />on it. <br />11. A fire door should be installed on the opening to the pipe shaft. <br />12. We found two five gallon cans of gas in the garage. These must be <br />removed. <br />13. We found evidence of careless smoking habits in some of the areas. <br />There were ash trays available but there were more cigarette butts on the <br />floors than in the ash trays. <br />14. The fan in the weights and measure room in the basement is located in <br />a c-rooden shaft. <br />15. Several places the conduit and switches need to he fastened to the wall <br />or coiling. <br />16. There are a fear light fixtures with improper wiring to theca. <br />17. The oil on the floor of the furnace room needs to be cleaned up. Also <br />the bench needs to be cleared of the furnace oil on it. <br />13. Remove old papers from the furnace room. <br />19. The windows opening into the old garage on the south side of the <br />building needs to be one hour fire protected or bricked up. <br />20. The outlet in the coffee room that comes out of the police dispatch <br />system should have another source of srpply and be disconnected from the <br />police system. <br />21. The cash register in the traffic office must be put on another circuit. <br />
The URL can be used to link to this page
Your browser does not support the video tag.