My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3120 WETMORE AVE 2016-01-01 MF Import
>
Address Records
>
WETMORE AVE
>
3120
>
3120 WETMORE AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2017 7:01:06 PM
Creation date
3/9/2017 1:38:51 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3120
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
177
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KL': 1:rst Baptist Church Mechanical Submittal MQ610-068, 3120 Wetmore Avcnue <br />{ <br />Meg Haley <br />From: <br />Sent: <br />To: <br />Cc: <br />Adam Clark [adam@oaryparkinson.cor�] <br />Tuesday. November 28, 2006 4:48 PM <br />Meg Haley <br />Steve Miller; Shellie Pons; Pele Gatfney; stevenk cGilgbs-hvac.com <br />Subject: RE: First Baptist Church Mechanica� Submittal M0610-068, 3120 Wetmore Avenue <br />Meg <br />Page I oi 2 <br />There are two Iocations where dcctwork peneVates more lhan lwo slories. One is near grib B and 2, the olher is in the janitor <br />rooms o�� the first and second floors <br />My s! ��gestion to the contractor is as follows: <br />Conslrucl a one-hour conlinuous shaft lhal encompases all of the ductwork that runs betNeen the (irst floor and roof. The shaft <br />can be terminated at the underside o( the Lrst floor with a fire damper per IBC 707.11.3. All ductwork elc. tha[ penetrales the shaft <br />will need to be protected as described in IBC 712 (basically, fire dampers at all ducl penetrations). <br />I hope ,: will clari(y lhis issue for everyone. Please feel free to give me a call if necessary. <br />Thanks, <br />Adam Clark <br />Gary Parkinson Architecls <br />(425) 252-2153 <br />From: Meg Haley [mailto:MHaley@ci.everett.wa.us] <br />Sent: Monday, November 13, 2006 9:33 AM <br />To: Adam@GaryParkinson.com <br />Ce: Steve Miller, Shellie Pons <br />Subject: RE: First Baptist Church Mechanical Submittal M0610-068, 3120 Wetmore Avenue <br />Adam, <br />Are there any revisions for the mechanical or architectural permit submittals on lhis project for shafl penet�ations? The contractor <br />requested clarification in a scheduled permit inspection lhis morning, but we did not have any revisions on file yet. Thanks! <br />-Meg <br />From: Meg Haley <br />Sent: Thursday, Novembcr 02, 200G 4:59 PM <br />To: 'AdamC�GaryParkinson.mm' <br />C[: Stevc Plillcr, $hcllic Pans <br />Subjeet: Firsl f3aptisl Church Medianical SubnuUal MOC>10-0(A3, 3120 Wetmorc Avenuc <br />Adam, <br />Thanks for taking my call today I have aitached some excerpts from the mechanical submittal that show ducts penetrating more <br />than two occupied (loors (along column line B-2). Ted Budden, our Chie( Inspector noled the penetration at B-2 after a field <br />inspection last week. There may be other similar conditions. We released the mechanical submittal today for permit. <br />Please copy us wilh architectural drawing revisions to accommodate the mechanical system as designed, or have the mechanical <br />contractor submit a revised layout as required to meet the intent oF IBC Section 707.2, Shaft Enciosures. Thanks for your offer to <br />contact the General Contractor to expedite resolution of this issue. <br />I I /29/'_006 <br />
The URL can be used to link to this page
Your browser does not support the video tag.