My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3614 WETMORE AVE 2018-01-02 MF Import
>
Address Records
>
WETMORE AVE
>
3614
>
3614 WETMORE AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2022 11:32:08 AM
Creation date
3/9/2017 2:06:42 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
3614
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
157. <br />Garages for the storage of private pleasure cars <br />should be designed for a minimum 2000 pound <br />wheel load. Section 2302 (b). <br />158. <br />Live load signs are required. Section 2309. See <br />.......................................................................... <br />159. <br />Glued -laminated lumber should be fabricated in <br />accordance with Section 2511 M. <br />160. <br />Allowable stress in glued -laminated members <br />over 12 inches in depth should consider a <br />depth reduction factor. Section 2511 (d) 6. <br />161. <br />Bolted connections exposed to the weather are <br />limited to 75 percent of the allowable load <br />under protected conditions. U.B.C. Standard <br />No. 25 17. <br />162. <br />Anchorage of concrete and masonry walls shculd <br />comply with Section 2313. <br />163. <br />Plywood grades shc�ld conform with Table No. <br />25 B. <br />164. <br />Justification is required that sufficient slope or <br />camber is available to assure adequate roof <br />drainage after long, time deflections. In lieu of <br />this, roofs must be designed for possible pond- <br />Ing of water. Section 2305 (e). <br />165. <br />Details on stressing method and hardware along <br />with justifying data are required cn prestressed <br />concrete work. This data should be submitted <br />and approved prior to ordering of material. <br />Note that all tendops should comply with Sec- <br />tion 4303 (c) 3, for fire resistive purposes. <br />166. <br />Welding data or details for steel decking used as <br />a diaphragm should be provided. Information <br />should comply with a specific ICBO research <br />recommendation or test data submitted in <br />compliance with Section 106. <br />Additional Corrections: <br />167. <br />Details should be provided on roof (floor) dia- <br />phragm cuenections that indicate how the <br />shears are transferred to vertical shear -resist- <br />Ing etements. Connections should be justified <br />- <br />with structural calculations for compliance with <br />allowable values. <br />168. <br />Nailing for gypsum board (lath, sheathing board) <br />used structurally on shear walls should be <br />specified to comply with Table No. 47-I. <br />169. <br />Shear v:alls utilizing gypsum board (lath• sheath. <br />ing board) cannot be used to resist loads im- <br />posed by masonry or concrete walls. Footnote <br />1, Table No. 47-I. <br />170. <br />Raslings should be designed to withstand a 20 <br />(50) pound per foot horizontal force. Table <br />No. 23-C. <br />171. <br />Ceiling joists should be designed for total load <br />of not less than 10 (20) pounds per square <br />foot. Table No. 23-C. <br />172. <br />Interior partitions should be justified structurally <br />for strength and deflection criteria specified in <br />Section 2312 M. <br />173. <br />.................................................... should comply <br />with a specific ICBO research recommendation <br />or justifying test data should be submitted in <br />compliance with Section 106. <br />174. <br />Plans should indicate that foundations extend <br />below the frost line. <br />175. <br />Provide complete specification in conformance <br />with the design for ................. ........................ <br />wll- <br />-rnoJ n00 <br />' Awl n(Lhy.J l)-z Cos Sc'. F+Lt R� S"fA�Pc..�- f?'/ A WA�.I'": T,�'Ai l•`fl�.—f�`. <br />R • r l c'-f SQL r. tea• r-rr (C c-t o �t ' ?�' � 1 �:iP <br />These sheets are a part of the plans and shall remain attached thereto. Corrections as above Indicated will be complied with. <br />Recheckedand Approved ...... ................. _.........._..........................._.........(Sign Here) .......... :............................................................... <br />(signalum of Owner or Applicant) <br />Data .-_._............ .............. .... ... _............................. checked by ................. _.......... :............ __._.............. ............ <br />, <br />r <br />Date ..................... _............... ................................................ <br />Sheet No. 6 of G Sheets <br />
The URL can be used to link to this page
Your browser does not support the video tag.