Laserfiche WebLink
C <br />�=d= <br />�,»,«,��, <br />�s.m�, <br />required to be insulated to R-21. Show 2x6 framing in ti�ese locations. Show <br />walis at center dortner on "upper plan view." <br />13. The elevatlon view of the rear of this house shows transom windows in the <br />master bedroom but tl►e roof framing wlls out "pre-engd flat trusf." Please <br />clarify. <br />14. Label all windows "safety glass" in hazardous locatlons per R308 IRC. <br />15. The roof overhang at the north side of the master bedroom projects into the 5'- <br />0" setback. Projecttons that extend into tfie 5'-0" setbadc are requfred bo be <br />protected on tfie underside with one-hour fire-resfstive construction per Table <br />R302.1 IRC. Provide detail of projection with one-hour fire-resistive protecHon <br />on tfie underside. <br />16. Show how cantllevered floor joists are ventilated. <br />Plasse prepare a response let�er showiny where aach ibam in tfifs aortection letber is <br />addressed on the pisn set <br />Upon resubmittal of the drawings, your applicatlon will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain suflident infortnadon to ensure <br />that tfie oroposed structvre will be constructed in rnmpliance with all adopted codes. <br />Sincerely, <br />�� <br />]e(f Heilman <br />Development Technician <br />425-257-8976 <br />Email: jhP�iman@ci.everett.wa.�s <br />yYmNsoNl�eMnwptl111-0]2 (6771 WebMe Me) <br />