My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
512 WINTON AVE 2016-01-01 MF Import
>
Address Records
>
WINTON AVE
>
512
>
512 WINTON AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2017 12:11:12 PM
Creation date
3/9/2017 3:24:59 PM
Metadata
Fields
Template:
Address Document
Street Name
WINTON AVE
Street Number
512
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11. Specify u-value of ezterior door(s). <br />Elecvic Heat U-0.20 <br />Other Heat U-0.40 <br />12. Show attic ventilation. <br />13. Provide rypical wall section from footings to roof trusses. Show and label all components <br />including but not limited to: <br />Footing, stem wall, anchor bolt, sill plate (pressure treated), rim joist, floor joists, tloor <br />sheathing, bottom plate, studs wall sheathing, siding, interior wall finish (gypsum,wall <br />board) double top plate (lap splices 48") rypical header size (size species and grade). <br />Roof trusses, vented blocking, roof sheathing, moismre barrier, roofing. Also refer to <br />items �3, 4, 5, 6, 7& 9. <br />14. Provide coof-framing plan. Show all hips valley's and ridges and if applicable show any <br />special avsses, i.e. hip master girder truss, etc. <br />15. Specify siu species and grade of over framing of roof adjacent to addition. <br />16. All sheets in plan set shall be the same size. Number each sheet and staple into 2 sets. <br />17. Specify type of heat on plans. <br />18. Habirable rooms shall be provided with nacural light by means of exterior giazed openings <br />with an area not less than one tenth of the floor area with a minimum of 10 s.f. The <br />kitchen is defined as a habitable room. <br />19. Habitable rooms shall be provided with natural ventilation by means of openable exterior <br />openings with an area of not less than one twentieth of the floor area with a minimum of 5 <br />s.f. A mechanical system may be substituted for an exterior opening. <br />Provide a response letter showing where each item in this correction letter is addressed on the <br />plan set. <br />Upon resubmital of the drawings, your application will be given prioriry and plan review will <br />commence. <br />All required submittals shall be of sufficient detail and contain su�cient information to ensure <br />that the proposed structure will be constructed in compliance with all adopted codes. <br />Sincer y <br />� �� <br />Je Heiiman <br />Development Technician <br />JH:jN9808-29 <br />�3 <br />