Laserfiche WebLink
Geotechnical Enginecring Lettcr <br /> 3505 Shoro Avenue Dxk Addition <br /> Everett,Washiaglon <br /> May 26,2010 <br /> NGA File No.827110 <br /> Page 9 <br /> Deck Foundations <br /> Conventional shallow spiead foundetions tor the deck addidan strould be placed on undistucbed medium <br /> dense or better native soils. 'Ihese soils were rncountered approximetely 2A to 4.0 fat below ground <br /> surface in our explorations. Where undocumcntcd fill or less dease soils are cncounuccd a[the planned <br /> footi�g elevation, the subgade should be over-cxcavated to expose suitable bearing soil. 'il�e over- <br /> excavation may bc filled with swctural fill, or the footing may bo extended down to the beazing na6ve <br /> soils. If footings aro supported on swctural fill, the fill zone should extend outside the edges af the <br /> footing a distance equel to one-tialf of the depth of the ovcr-excaveNon below the bottom of the footing. <br /> The dcck footings should extend at least 18 inches below t6e adjacent finished ground surface for frost <br /> protccdon and bearing capacity consideraGons. Foundalions should be designcd in accordance with lhe <br /> 2006 Tntemational Building Code (1BC). Footing widths should be based on the anticipated loads and <br /> �Ilowable soil bearing presswe. \Water should not be allowed to accumulate in footi¢g trenchea. All <br /> loose or disturbed soil should be removed from the footing excavatior prior to placing concrete. <br /> For foundations consWcted as outlincd ebove, we rocommend an ellowable design bearing pcsssure of <br /> not more thxn 2,000 pounds per square foot (ps�be used for the de;igo of foundations suppoRed on tLo <br /> medium dense or better native soils or stnictural fi11 extending to the competent nebve soils. A <br /> representative of NGA should evaluate the foundaHon bearing soil. We should be consulted if higher <br /> be`ring pressures are needed. Cumnt IBC guidelines should be used when considering increased <br /> allowable bearing pressure for short-term transitory wind or seismic loeds. Potential foundation <br /> settlement using the recommended nllowable beaiing pressu�c is estimaled to be less than one-inch total <br /> mid %:-inch differentia! between adjacent footings or across a distance of about 30 fcet based on our <br /> experience with similar projects. <br /> Lateral loads may be resisted by fi-iction on tbe base of the tooting and passive resistance against the <br /> subsurface pofions of the foundaHon. A coe8�icient of friction of 0.35 may be used to calculate the bau <br /> friction end should be applied to tk�e verticel dead load only. Passive resistsnce may be calculated as a <br /> Uiangular equivalent Eluid presswe distribution. An equivalent fluid density of 200 pounds per cubic foot <br /> (pc�should be used for passive resistance design for a level ground surface adjacent to the foodng. T6is <br /> level surface should extend a distance equal to et least three times tho footing depW. 'Ihese recommended <br /> NELSON GEOTECHNICAL ASSOCIATES, INC. /�/�j <br />