Laserfiche WebLink
CITY OF EVERETT <br /> B�IILI)ING INSPECTIOP! DEPART�4ENT- <br /> (206) 259-8745 <br /> Date September 22, 1986 <br /> Everett Builders <br /> 5606 Everareen Wav <br /> Everett WA 98203 <br /> RE: Owner Robert Weis <br /> Job Address 1713 Silver Lake Rd <br /> Plan Check No. 86/17171 <br /> In response to your application for a construction permit, your plans have been <br /> examined and you are ;advised that the issuance of a permit is being withheld <br /> for the reasons listed below. <br /> In order for processing of your application to continue, it will be necessary to <br /> provide the Building Department with two new sets of drawings reflecting the <br /> corrections requested. <br /> Upon resubmittal of the drawings, your application will be given priority and <br /> plan review will recommence. <br /> Item No. <br /> 1 . Header sizes not indicated, <br /> 2. Anchor bolts to be spaced at 4'-0" oc, <br /> 3. Glazing U-value to be 60 or less (Washington State Energy Code) . <br /> 4. 6" minimum distance required from grade to siding. <br /> 5. R-38 required in flat ceilings; R-19 with vapor barrier in walls. 2 x 4's <br /> indicated in walls will require'a comtination of batts and rigid insulation; <br /> indicate combination to be used. <br /> 6. Re existing window headers over 6' openings. Placement of second story <br /> windows creates unit load which exceeds allowable in vertical shear and <br /> bending if existing headers are 4 x 8's or smaller. Suggest relocation of <br /> new windows to bear on stud walls. <br /> � ��IS J(4'r-t <br /> Sue Grannan <br />