Laserfiche WebLink
. <br /> . <br /> � - <br /> � Botesch, Naah & Mall <br /> Architects, P.S. <br /> August 25, 1999 <br /> City of Everett <br /> Engineering/Public Services Department ���� �� <br /> 3200 Cedar Street \\ � � <br /> Everett, WA 98201 � G \% <br /> .Attn.: Tony Lee, Plans Examiner �� P1�G�,51999 <br /> RE.� PlandCh ckrNo. B99I07!021 Y QF 5e�c�.p� <br /> For: Rodgers Electric Building Cti�Pe��`�� <br /> 3826 Smifh Avenue <br /> Everett, WA 98201 <br /> Dear Tony: <br /> Thank you for your review comments dated August 12, 1999. Attached are revised drawings and <br /> supplemental structural engineering doc�mentation. Please recommence your plan review so <br /> that the owner can get construction undervvay at the earliest date. <br /> The corrective actions for your comments are as follows: <br /> General <br /> i �1� Exhaus?for restroom moisture fans: Dwg Sht. A1.1 has been noted to indicate <br /> that the exhaust is to be routed to penetrate the west wall. <br /> 2: Skylight glazing: Dwg. Sht. A1.3 has been noted to indicate <br /> � laminated glass or screens. <br /> 3. Window"I": Dwg. Sht. A7.1 has been noted to indicate <br /> Safety Glass for this window. <br /> Accessibility: <br /> 1.' Van accessible parking: Dwg. Sht. SP1.1 has been redrawn to <br /> J provide a van accessible parking space at the iront door. <br /> 2. Flush controls Dwg. Sht. A1.3 has been noted to indicate <br /> that flush controls are to be mounted on the side farthest from the wall. <br /> 3. Drinking fountains: Dwg. Sht.'s A1.1 8 A1.3 have been redrawn <br /> & noted to indicate high & low drinking fountains on the south face of the south wall of <br /> the restrooms. <br /> Structural: <br /> 1. Sealed drawings: Structural Dwg. Shts. S1.1, 1.2 8 1.3 have <br /> been sealed to ar,company the sealed structural calculations submitted previously. <br /> 2. Rooftop HVAC units: Dwg. Shts. A1.:� & 3.1 have been noted to <br /> indicate that the HVAC units are to have a max. unit weigl�oi 395 Ibs. <br /> 3: Interior shear wall footing: Detail 11 on Dwg. Sht. S1.3 has been <br /> added. <br /> ��L <br /> 2915 Hewitt Avenue• Everelt, WA 98201 •425•259•086B• 425-7743341 •Faz 425-252•4334•e•mail bnh0bnharch.com <br />