Laserfiche WebLink
________________________________________________________________________________ <br />WATTSUN 5.6 1997 WA STATE $NERGY CODE COMPLIANCE REPORT 10/30/80 <br />FILE: C:\\WATTSUN5\\34065&L.WS HOUSE ID: PLAN 3406 <br />Site: <br />Homeowner: SMITH & LOHNES CONST <br />Builder: SMITH & LOHNES CONST <br />19521 1ST AVE SE <br />(425)730-8040 <br />Analyst: Ron Renard <br />Jurisdiction: CITY OF EVERETT <br />Utility: Gas <br />House Type: Single Family <br />Floor Area: 3406 ft2 <br />Weather Data: Seattle, WA <br />Climate Zone: 1 <br />The PROPOSED design *COMPLIES* with 1997 WA State Energy Code. <br />REFERENCE PROPOSED <br />COMPONENT PERFORMANCE 719 706 Btu/hr—F <br />ENERGY BUDGET 10.66 9.78 kWh/ft2—yr <br />REFERENCE DESIGN <br />Component <br />BG Wall 7' <br />BG Slab 7' <br />Floor <br />Glazing @158 <br />Doors <br />AG Wall <br />Ceiling, Attic <br />Infiltration <br />PROPOSED DESIGN COMPONENTS <br />Component <br />BG Wall <br />SG Slab <br />Description <br />R13 Batt 7' depth <br />Floor R19 vented Joist 16oc <br />Glazing @308 **MILGARD VIN XO STYLE. LOW—E ARG <br />Reference <br />Value X <br />U-0.037 <br />F-0.570 <br />U-0.041 <br />U-0.650 <br />U-0.390 <br />U-0.062 <br />U-0.036 <br />ACH-0.350 <br />Area = <br />81 <br />9ft <br />1638 <br />510.9 <br />38.0 <br />3832 <br />1638 <br />30654ft3( <br />Reference UA <br />Value X Area = <br />�U <br />UA <br />3.0 <br />5.1 <br />67.2 <br />332.1 <br />14.8 <br />237.6 <br />59.0 <br />196.3) <br />718.7 <br />UA <br />U-0.046 81 3.7 <br />F-0.545 9ft 4.9 <br />U-0.041 1638 67.2 <br />L'-0.360 573.5 206.5 <br />Items in parentheses not included in COMPONENT PERFORMANCE totals. <br />** Denotes non—stand�.rd values — check calculation of thermal value. <br />_____________________________________ Page 1 =____________________________----__ <br />`�3 <br />