Laserfiche WebLink
CI7Y OF EVERETT <br />giIILnING INSPEC7i0Pl DEPARTME�T <br />(206) 259-8745 <br />Novemher 25, 1986� <br />Date �- <br />� <br />Donald Herwander <br />5830 135th P1 NE <br />Marysville, WA ?8270 <br />RE; Owner ponald Herwander <br />,lob Address <br />Plan Check No. e6/1�4a1 <br />In response to your application for a construction permit, your plans have been <br />examined and you zre;advised that the is:uance of a permit is being withheld <br />for the reasons listed below. <br />In order for processing of your application to continue, it .. 11 be necessary to <br />provide the Building Department with two new sets of dra•.vinys reflecting the <br />corrections requested. <br />Upon resu6mittal of the drawings, your application will be given priority and <br />plan review will recommence. <br />Steel beam under wall between Dining Room and Kitchen is overstressed. <br />If hot water tank and/or furnace are gas-fired the'I should be mounted 18" off <br />the floor slab. If the hot water tank is ^_Lectric it must be installed on an <br />R-8 insulated pad. <br />2" x 8" hem/fir floor�joists at 12" o.c. over the Family Room exceed the <br />allowable span given in Table 25-U-J-1. <br />Provide 5/8" gypsum wallboard under stairs and on walls of the closet. <br />Floors over crawl spaces to be insulated with R-19 and supported. <br />Anchor bolts for sill plates to be 1/2" x 10" minimum and spaced at 4'-0" o•c• <br />Footings and foundation walls to be reinforced per City of Everett standards. <br />Sill plates to be pressure treated with preservative. <br />Revise Detail 6 Sheet 5 to show solid blocking over the steel beam and 4'-0" o.c. <br />Spacing of bolts. <br />Page One of Two <br />