My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1912 SUMMIT AVE 2016-01-01 MF Import
>
Address Records
>
SUMMIT AVE
>
1912
>
1912 SUMMIT AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2017 9:06:22 PM
Creation date
3/10/2017 12:54:29 AM
Metadata
Fields
Template:
Address Document
Street Name
SUMMIT AVE
Street Number
1912
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � -' � <br />Ltr. R. Oliver (C0401-006) <br />January 15,2004 <br />Page 2 <br />14. Provide post and footing at cach end of gircler in crawl space or specify requirements for beam <br />pockets. <br />I5. Verify maximum 44" finished sill height above floor in sleeping rooms. Provide note on drawings. <br />l6. Provide 36" landing not more than 8" below the finished Floor at exidentrance. <br />17. The exterior wall in the center bedroom is 2 x 4 at the existing house and 2 x 6 at the addition <br />please clarify. <br />18. Provide minimum 50 cfin exhaust fan vented to the exterior in each bathroom and the laundry <br />room. <br />19. Provide minimum 1/10 of the floor arca for natural light and I/20 of the floor area for namral <br />ventilation in each habitable room. The bedroom in the addition appears to be deficient. <br />20. The uniform building code requires 2" x 2" x 3/16" plate washers on all anchor bolts. <br />21. Corridors are requimd to be minimum 3'-0" clear width. If the plans show 3'-0" to the face of the <br />framing, the corridor would not be wide enough. <br />22. Provide solid blocking at top plate between manufactured trusses, and over the girder in the crawl <br />space. Show on plans. <br />23. Specify framing over existing rooE Provide valley flashing at valleys. <br />24. If soffits are ventilated provide insulation baffle per 502.1.4.5 Washington State Energy Code <br />(WSEC). <br />25. Show how new foundation is connected to existing foundation (minimum #4 rebar doweled into <br />existing @ 12" o.c.). <br />Please prepare a response letter showing where each item in this cortection letter is addressed on the plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will recommence. <br />Afl required submittals shall be of sufficient detail and contain sufficient information to ensure that the <br />proposed strucmre will be conswcted in compliance with all adopted cales. <br />Sincerely, <br />� �� <br />Jeff Heilman <br />De��cloptnent Technician <br />f)IiDITLNCAAISTMlf.11 \IA6�CTWIb1YM1I91: SCMAIITI Z�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.