My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2613 TAYLOR DR 2016-01-01 MF Import
>
Address Records
>
TAYLOR DR
>
2613
>
2613 TAYLOR DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/25/2017 7:40:34 PM
Creation date
3/10/2017 2:14:33 AM
Metadata
Fields
Template:
Address Document
Street Name
TAYLOR DR
Street Number
2613
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Apri129, i999 <br />Larry Grulet <br />P O Box 1029 <br />Everett WA 98206 <br />� <br />r/ec/c /i�a�cs <br />Subject Owner: Goulet <br />Job Addross: 2613 Taylor Dr. <br />Plan Check No.: 62180 <br />Jeaz � 4r. Goulet: <br />� <br />In response a� your application for a construction permit, your plans have been exart►ined and you are <br />advised that thr. issuance of a permit is being withheld for the reasons listed below. These comments <br />address build'uig issues on!y, additional revisions or additions may be required by other departments <br />(such as Utilities, Plann�ng or ,�ire). All roferences refer to the 1997 Uniform Building Code, as <br />amended by tt:e State of Washington and/or Washittgton State Energy Code 1997 Edition, uNess stated <br />otherwise. <br />In order for the processing of your application to rnntinue, it will be necessary to provide the <br />Building Division with two complete new sets of drawings retlecting the rnrcections requested. <br />The plans as submined do not mect the prescriptive requirements for lateral bracing per section <br />2320.4.1 and table 23-N-C-1 UBC. Provide laural analysis prepared by a licensed WA. St. <br />structural engineer for wi�xi and seismic loading. <br />2. Provide safery glass in hazardous locations per CH 24 UBC as shown on plans. <br />3. Provide stair detail(s) show all components of stairs and required fire resistive construction. <br />Show how roof is supported over new breakfast room. <br />Provide a respcnse letter showing where each item in this correction letter is addrcssed on the plan set. <br />Upon resubmital of the drawings, your application will be given priority ancl plan review will <br />commence. <br />All required submittals shall be of sufficient detail anc+ contain sufficient information to ensure that the <br />proposed structure will be constructed in compliance wrth all adopted codes. <br />Sin:erely, <br />/4� ���1.�-� <br />7eff Heilman <br />Development Tectmician <br />CITY OF EVERETT• 3200 Cedar Street • Everett. WA 98201 � 1425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.