Larson Engineerfng,Ina SUBJECT: U.S. CUStOrttS& SHEET NO. C-14 <br /> 5757 Phantom Dtive,Sun� Co0 Border Protection PROJECT NO. 5109013�.000 <br /> ' ' St.louis,M069042-2455 portAnqeles WA sv RV onrE 4/21/2009 <br /> J147N.4770 Fa%: ]74771.4712 <br /> v.w+v.larsonengr.com <br /> � Larson <br /> CHECK SHEAR PANELS <br /> Total Lateral Load: Pi,t:= Vd�, Pi,c=1645.4•Ibf <br /> CHECK TYPI�nL AWMINUM PANEL <br /> Ta:= 1.86kip SIIEET M-1F1 <br /> A:= 91n•G.02021n <br /> Allowable Tonsion Stress(3003-Nt4 Ailoy.,Spec.No.1,SHT.B-7) <br /> T, <br /> fa= — f�=10.23•ksi <br /> A <br /> Fa:= 10.5ks1 <br /> f, <br /> — =0.97 < 1.O O�C <br /> r, <br /> USE ALUMINUM PANEL AS STRAP BRAGNG <br /> IN PANELS AT WINDOWS IN LONG WALLS <br />