Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Slandard N601. <br /> r-� <br /> � 5� Connect side sewer per City Standard #'s 601, 602, 604. <br /> G. Conrect all rooftop downspouts to lhe side sewer. <br /> _ <br /> ( 7.; Connect rooflop downspouts to tne drainage syslem provided for lhis lof. <br /> 8. Rooflop runoff musl be discharged to a roof downspoul infillralion system per Cily of Everetl Sbrm <br /> Manual 3-2.6.2. The approximale size trench is 3.5'wide,2'deep and 25'long. See altachment for <br /> more delails. <br /> 9. The contractor musl meet wilh lhe Public Works Inspeclor to discuss potential drainage routing prior to <br /> beginning the projecl. <br /> �10. ` Install erosion control measures as delermined by lhe Public Works inspeclor, such as silt fence, straw <br /> — ' bales, swales, or erosion blankels. <br /> 11. Inslall erosion control measures per City of Everett Standards for small parcels <br /> �2., Remove erosion conlrol measures upon complelion of the pro�ect prior lo final approval o(the permit. <br /> (13. All excavated malerial from foundalion, sidewalk and driveways shall be hauled to an approved, <br /> permitted site. No wasting o(material is allowed on this building lot. <br /> 14 No dirt, mud, rocks or debris to be tracked onto roadway. <br /> �_.` <br /> �-<v1l'.�il�/ F-cv1f�N.'J,N <br /> 15. No building materials to be slacked on sidewalks and sidewelks to be kepl Gean and open for <br /> pedes{riflR Iravel. <br /> v'ihci� <br /> 16. Adjusl water meler box 1"abuve sidewalk graae. <br /> 17. Remove and rep!ace curb, gutler and sidewalk as per Cily oi Everett Slandard Plan #'s 305A S 30G on <br /> this proposal's fronlage as directed by lhe Public Works Inspeclor(i.e. all unused driveways and any <br /> broken or damaged area musl be replaced). <br /> 18. Install a Type I concrete driveway per Cily of Everett Standzrd�307. <br /> `t9. Pave driveway(rom the front property line out to�he street paving. <br /> 20. Contact the Water Districl(or connecting provisions for this buildinc3's waler and <br /> sewer services. <br /> i <br /> 21. A catch basin as per Cily Standard Plan#402 wilh a gas trap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be installed, lhe pressure line must discharge into a private manh�.;, then <br /> �revity flow across the public right-of-way. <br /> 2�. A sprinkler syslem is required for this building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> FOR PUBLIC WORKS INSPECTION, CALL RANDY AT 425339-7403/CLIFF AT 425•339-7404 <br /> F�.;,� �,�a�r �� <br />