Laserfiche WebLink
Project Info <br />Project Address Everett cosgnity College <br />Date 4/1012005 <br />2000 row. stv..t 1206 olyvmu. a.111 <br />For Building Department Use <br />Everett NA 98201 <br />Applicant Name: .b.e1 E... <br />a <br />Applicant Address: s.e ee ebov. <br />Applicant Phone: 425-318-9253 <br />Project Description [] New Building ❑ Addition ❑ Alteration ❑ Change of Use <br />Q Prescriptive ❑ Component Performance ❑ ENVSTD 2.1 ❑ Systems <br />Compliance Option (See Decision rluwchart(over)for qualifications) (i.0not acceptable) Analysis <br />Space He.- t Type <br />Q Electric resistance QQ An other (see over for definitions) <br />Total Glazing Area Electronic version: th3se values are automatically taken from ENV-UA-1. <br />Glazing Area Calculation <br />(rough opening) Gross Exterior <br />Note: Belowgrade walls maybe lncludedin the <br />(vertical& overhd) divided by Wall Area limes 100 equals °a Glazing <br />3.2104.0 r 31303.0 X 100 = 38.7% <br />Gross Exterior Wall Area d They are insulated to <br />the level required for opaque walls. <br />Concrete/Masonry Option <br />O yes Chock here d using this option and it project meets all requirements for the Conct utmasomy <br />O no Option. See Decision Flowchart(over) for qualifications. Enterrequirements for each qualifying <br />assembly below. <br />Envelope Requirements (enter values as applicable) <br />Fully heated/cooled space <br />Minimum Insulation R-values <br />Roofs Over Attic <br />NA <br />All Other Roofs <br />21.0 <br />Opaque Walls' <br />11.0 <br />Below Grade Walls <br />10.0 <br />Floors Over Unconditioned Space <br />19.0 <br />Slabs -on -Grade <br />10.0 <br />Radiant Floors <br />INA <br />Maxintual U-factors <br />Opaque Doors <br />0.600 <br />Vertical Glazing <br />0.500 <br />Overhead Glazing INA <br />Maximum SHGC (or SC) <br />Vertical/Overhead Glazing <br />0.450 <br />Semi -heated space g <br />Minimurn Insulation R-values <br />Roofs Over Semi -Heated Spaces' uA <br />1. Assemblies with metal framing must comply with overall I factors <br />2. Refer to Section 1310 for qualifications and requirements <br />Notes: <br />Opaque Concrete/Masonry Well Requirements <br />Insulation on interior - maximum U-factor is 0.19 <br />Insulation on exterior or integral - maximum U-factor is 0.25 <br />If project qualifies for Concrete/Masonry Option, list walls <br />with HC = 9.0 Btu/IF°°F uMow, (other walls must meet <br />Opaque Wall requirer,ents). Use descriptions and values <br />from Table 20.5b in fne Code. <br />Wall Description U-factor <br />(including Im nation R-value & )ositionr <br />