My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Trinity Contractors, Inc 3/1/2017
>
Contracts
>
Capital Contract
>
Trinity Contractors, Inc 3/1/2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2018 10:38:25 AM
Creation date
3/10/2017 2:24:32 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
Trininty Contractors, Inc
Approval Date
3/1/2017
Council Approval Date
2/1/2017
Department
Public Works
Department Project Manager
Ryan Sass
Subject / Project Title
Citywide Intersection Signing Project
Public Works WO Number
PW3628
Tracking Number
0000497
Total Compensation
$653,910.20
Contract Type
Capital Contract
Retention Period
10 Years Then Transfer to State Archivist
Document Relationships
Trinity Contractors Inc 4/3/2017 Change Order 1
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
Trinity Contractors Inc. 5/4/2018 Change Order 2
(Contract)
Path:
\Documents\City Clerk\Contracts\Capital Contract
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
346
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 1 <br /> 2 1. Twenty percent CSS-1 emulsified asphalt, <br /> ' 3 <br /> 4 2. Two percent portland cement, and <br /> 5 <br /> ' 6 3. Seventy-eight percent fine aggregate meeting the requirements of 9-03.1(2)B <br /> 7 Class 2. Fine aggregate may be damp (no free water). <br /> 8 <br /> ' 9 9-04.2(2) Poured Rubber Joint Sealer <br /> 10 The last paragraph is deleted. <br /> 11 <br /> ' 12 9-04.4(1) Rubber Gaskets for Aluminum or Steel Drain Pipe <br /> 13 "AASHTO M198" is revised to read "ASTM C 990". <br /> 14 <br /> ' 15 9-04.4(3) Gaskets for Aluminum or Steel Culvert or Storm Sewer Pipe <br /> 16 In the last sentence, "AASHTO M198" is revised to read "ASTM C 990". <br /> 17 <br /> I18 9-07.AP9 <br /> 19 Section 9-07, Reinforcing Steel <br /> ' 20 August 1, 2016 <br /> 21 9-07.1(1)A Acceptance of Materials <br /> 22 The first sentence of the first paragraph is revised to read: <br /> 23 <br /> 24 Reinforcing steel rebar manufacturers shall comply with the National Transportation <br /> 25 Product Evaluation Program (NTPEP) Work Plan for Reinforcing Steel (rebar) <br /> ' 26 Manufacturers. <br /> 27 <br /> 28 The first sentence of the second paragraph is revised to read: <br /> ' 29 <br /> 30 Steel reinforcing bar manufacturers use either English or a Metric size designation while <br /> 31 stamping rebar. <br /> ' 32 <br /> 33 9-07.1(2) Bending <br /> 34 The first two sentences of the first paragraph are deleted and replaced with the following two <br /> 35 new sentences: <br /> 36 <br /> 37 Steel reinforcing bars shall be cut and bent cold to the shapes shown on the Plans. <br /> ' 38 Fabrication tolerances shall be in accordance with ACI 315. <br /> 39 <br /> 40 9-10.AP9 <br /> 41 Section 9-10, Piling <br /> 42 August 1, 2016 <br /> 43 9-10.3 Cast-In-Place Concrete Piling <br /> 44 This section is revised to read: <br /> 45 <br /> ' 46 Reinforcement for cast-in-place concrete piles shall conform to Section 9-07.2. <br /> 47 <br /> 1 <br /> AMENDMENTS TO THE 2016 STANDARD SPECIFICATIONS BOOK <br /> Revised: 8/1/16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.