Laserfiche WebLink
FLOOR PLAN NOTES: <br /> '2X6 H/F#2 EXTERIOR STUD WALLS @16"O.G.1A/DEL TOP PLATE& <br /> LAPPED 48"MIN. <br /> 'R-21 IN-WALL BATT INSULATION WNAPOR BARRIER. <br /> '2X4 EXTERIOR STUD WALLS @ 16"0.0.@ GARAGE. <br /> 'REFER TO FRAMING PLANS FOR BEAMS&HEADERS <br /> 'REFER TO ELEVATIONS FOR PLATE HEIGHTS. <br /> 'FIRE BLOCK ALL PLUMBING PENETRATIONS. <br /> 'PROVIDE SOLID BLOCKING OVER BEAMS&BEARING WALLS/ <br /> R502.7 <br /> 'ALL HANGERS/STRAPS BY SIMPSON OR EQUAL <br /> ElDENOTES SOLID POST OR DEL STUD POST LAMP TOGETHER <br /> WITH 161)(2)EACH END THEN 12"0/C STAGGERED,U.N.O. <br /> SAFETY GLASS/R3(2.4 <br /> <45) SG'TO BE PROVIDED IN DOOR ASSEMBLIES AND WITHIN A 24"ARC OF <br /> HINGED EDGE OF A DOOR&GLAZING 15 LESS THAN 60"A.F.F. <br /> 36'-0' 'WITHIN ENCLOSURES FOR TUBS&SHOWERS WHEN BOTTOM OF <br /> / -. / GLASS 15 LE55 THAN 60"ABOVE THE STANDING SURFACE. <br /> 'WHEN GLAZING 15 LESS THAN 15"ABOVE THE FLOOR AND HAS <br /> / Ib'-I' 9-;' 10'-1' / GLAZING AT STAIRWAY LANDMORE THAN 9 SQ.FEET OF INGS AND WITHIN 60"HORIZ.,OF <br /> 5.3' 1-10' 2'-10' 6=6" <br /> SUCH LANDINGS WHEN BOTTOM EDGE OF GLAZING 15 LESS THAN <br /> BO"ABOVE <br /> FLOOR. <br /> NISHED <br /> / 1 � 'SKYLIGHTSITO COMPLY WITH SECTION R305.6. <br /> LANDINGS PER 8311.3 <br /> 1.-STAIR WELL ILLUMINATION PER R.303.6 <br /> 1Al 504085 f1s' 3030R5 55 ALa <br /> 1 TUB,SHOWER,W/C:TO COMPLY WITH R 301.2 OPT.3a <br /> N <br /> a/ - { f WATERPROOF BACKING+72"MIN.ABOVE DRAIN INLET.R102.4.2 <br /> i PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES SHALL <br /> /`\ la <br /> PROVIDED FOR SHOWEER5 AND TUB/SHOWER COMBO @ 1.75 <br /> 4 \• / r''" ' PROVIDE SAFETY GLASS ON ALL ENCLOSURES. <br /> m <br /> ALL PLUMBING FAUCETS TO HAVE A1.0 GPM FLOW RESTRICTOR. <br /> MASTER BDRM CLOSET m WlGTOUSE 1.6GALLON MAX PER FLUSH. <br /> s a M�tSTER BATH �ii — <br /> � . <br /> 6 ATTIC.AGGE55/8807.1 <br /> L� -- _"---_- 22X30'MIN.CLEAR OPENING,WITH 30 MIN.CLEAR HEADROOM <br /> - LOCATED IN HALLWAYS OR OTHER READILY ACCESSIBLE AREAS, <br /> - ' "- INSULATEAND WEATHER-STRIP ____ <br /> -ro } <br /> WHOLE HOUSE FAN PER 2012IEGG <br /> I\///��'''���) I 72'24 HR TIMER,1.5 SONE MAX <br /> C)C/ O ; 1 I _ ' R-4 DUCT INSULATION_ <br /> ♦ , 'S .-�..SMOKE ALARMS SHALL BE INSTALLED IN THE <br /> I2'..?.' _ ( " -N 360CF —' • ,FOLLOWING LOCATIONS:(SECTION 83143) <br /> /- / 1y2 O BEDROOM 2 1.EACH SLEEPING ROOM <br /> 2.OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY <br /> Q SD 5., BATH- Q S OF THE BEDROOMS <br /> iii <br /> ^}'•._ 4 I'SMOKE ALARMS SHALL BE INTERCONNECTED AS INDICATED IN <br /> 3'•9' 6'-IO' SECTION 8314.3 <br /> \ ` - ••-^-- " 2668-=- �/ <,7> - / ri 'THE POWER SOURCE FOR SMOKE ALARMS SHALL COMPLY WITH <br /> /�_��} _ o SECTION 8314.4 <br /> �� 5� '/- -`col••CARBON MONOXIDE ALARMS SHALL ALSO BE INSTALLED <br /> I �/ 50 m -'� OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE <br /> I VICINITY OF THE BEDROOMS(SECTION 8315-1,8315.3) <br /> 9 c / 3'•3 U2° / I - 4 <br /> r \" 2068--2668 q - 2668 •___ - m <br /> --36"+1f2 WALL HALL L-vNm 1 5063 <br /> C��S0�,I <br /> o2 <i M 1 <t S' m v '- (C1 tirA\trs eucV\ -2y � <br /> • h� vs <br /> L--J (( •t .t <br /> ♦ ..._„, n� — -2868-J.:.. \.».. -----8068: r.i. 2668 c Y1 u�J' ?lir y U`�-' <br /> 11 �. . 5068 r <br /> O 1 50 <br /> 2 <br /> LAUNDRY,a,, 2'1. / 4'-6' 6-10 <br /> J / /1 <br /> ♦ _ . <br /> , ._, 4033R5 r �, BONUS BEDROOM.3 4 <br /> 9 <br /> 5042R5 1A Q <br /> : I <br /> ON" 604 R5 1 <br /> P 1 <br /> I <br /> /i II'-S I/2' f p.-0 1/2' / 11.2' / <br /> I <br /> I 1 <br /> SHEAR WALL TYPE PER A <br /> r '- SCHEDULE ON SHT S-1 5_ / AO/ 06'-0' / <br /> _:;.r:CiLP.;•.I.,:r''I;;; / /4 0 <br /> :co :.: T A <br /> HAACK BROTHERS <br /> / Makayla Park, <br /> ///// /'SHEET 1 <br /> P/ 6152015 Rj <br /> UPPER OOR PLAN ' <br /> 1/4-=1•-0,• OF 9 <br /> Not inc.DSS SM@ <br />