<br /> � H� O O Q Exposed foam Insulatlon shall comply as tollows(S.502.1.4.7):
<br /> y �'r ❑ Prolecled with mPtal o�plaslic flashing, or other suitable material that extends below grade.
<br /> .�,., o ❑ Insulation is approv�d tor sub-grade,exterior use and properly installed.
<br /> ''3 d ❑ 17� Q� Alrflow between iresh air ports and ihe whoie•house fan ensured by undercut doors/grills(VIAQ,S.302.6.4)
<br /> H �g O �Ji�Loose(III InsulaUon OK il (S.502.t.4.5):
<br /> �„ � ❑ maximum ceiling siope nol>31n 12
<br /> �"' r'-a p230"ot ciear distance from top of bottom chord to underside of roof shealhing al the roof ridge.
<br /> a H� p � .ans 6 mll black polyethylene ground cover, shail be lapped 12"at Joinis and extend to toundation wali
<br /> C H y ❑ d fGSClearances shall meet listed minimums between insulalion and(S.502.1.4.3):
<br /> � �� ❑chimney ❑Non-IC rated recessed lights: 1/2"to combustabies,3"to Insuiation.
<br /> � � Attic hatch shall be insulated to required ceiling R-value and is weatherstripped(5.502.1.4.4)
<br /> � t�� p p Attic acc?ss shall have wood dam or oquivaient to retain loose fiil Insuialion in attic(S. 502.1.4.4)
<br /> z �cn O �i1 9 All exterlor doors (except 20 minute doors) shall 6e wealherstripped (S.502.4.3).
<br /> ' '�C0 p pij o Servlce hot&cold water plping in unconditioned spaces shall b�:Insulated to R•3(S.503.11)
<br /> p �j � Servlce reclrculatlon het water plping in unconditioned spaces shall be insulated to Table 5-12 levels.
<br /> O p Qz Heat pump thetmostat shall have progamable capability(S.503.8.3.5)
<br /> p p ,��s]Thertnostat provided tor each HVAC system with range of�5-75' F.(heating) (S.503.8.1.1).
<br /> 0 0 �Readlly accesslble,aut�matic or Manual means provided to reslrict or shut-oft Heating input lo each
<br /> zone or tloor during periods not requiring heal(S. 503.8.3.1).
<br /> I `. - ,� p � s ontrols(or bsckup heat prohioit simiitaneous operation ot the primary system (S.503.2.2(3)).
<br /> ,.� p � s echanlcal ventllatlon system shall have proper timers,and/or switches(VIAQ,S.302.3).
<br /> p � echaNcal venUlatlon ducts shall have R-4 insulation in un ond_� itionad spaces (VIAQ,S.302.5)
<br /> p � s echanlcal venlllatlon supply ducts in r.ondilioned spaces shall have R•4 insu;ation(VIAQ,302.5)
<br /> j p p a upply ducts shall have volume dampers,or the equivale�it,to balance system(S.503.6).
<br /> O p o upply and return aly ducts shall have sealed duct joint;:in unconditioned epaces (S. 503.102).
<br /> p ❑ i VAC plenums,supply,and return aly ducts shall have H-8 insulation(Table 5-11,Ail oplions)
<br /> 0 p z leclrlc water heater(s) shalt have(S.504.2.1,504.3,504.4) :
<br /> �. ❑separale power shut-off ❑ 1987 NAECA Lable on tank
<br /> ❑noncompressible R10 pad (unheated spaces only) O ?omperature setting s 120 F.
<br /> � ❑ �howers a�d lavatodes shall limit Ilow to s 3.0 gallons/min ite (S.504.8.1).
<br /> ( p p �Swimming pools(S.504.5) s.iall have:
<br /> ❑readily accessible ON/OFF switch(pump, hea�er) pPool cover ❑Piping insulaled to S.503.11
<br /> p �J �A,II(Ireplaces (VIAo,S.402.3)shall have:
<br /> p o 6 square inch combustion air supplyducl w/accessible damper directly connected lo ihe lire box
<br /> ` ❑Tight litting glass or metal doors. o Tight titting flue damper
<br /> ❑ n s Solid tuel burnlnE;o�pllance(s) (VIA4,S.402.2)shall havo:
<br /> � ❑Tight fitting glass or metal doors
<br /> - o0utside wmbustion air source direcll�cor,nected to thn fire box
<br /> pException:Non-direct,4"diameter,damFared,combustlon air source:allowed only tor(1) new stove
<br /> I installalions in exis�ing homes where obslr:ctionsprecludes direct combust�n air,or(2) Cenlral
<br /> -_-- healing syslems located in unheated cpaces.
<br /> p p � Three month,etched track radon monUnr,printed instruction=, and iniormation sheets shai;�e supplfed