Laserfiche WebLink
e. Marquee <br /> Design Amenity Design Criteria FAR Bonus <br /> A permanent overhead 1. Must be developed 5:1, measured as gross <br /> canopy projecting over a walkway or square footage of per- <br /> from the facade of-a sidewalk. mitted development for <br /> building, and designed each square foot of <br /> to provide continuous 2. Pavement below must public sidewalk covered <br /> overhead weather pro- be constructed to by qualifying marquee. <br /> tection to the area provide for drainage. <br /> underneath. <br /> 3. Must have a horizontal <br /> rather than sloping <br /> orientation along the <br /> building elevation. <br /> 4. Design must be coordi- <br /> nated with building <br /> design. <br /> 5. Minimum height is 8' <br /> above finished grade, <br /> except as otherwise <br /> required in the Uniform <br /> Building Code. <br /> 6. Maximum height is 12' <br /> above finished grade. <br /> No bonus is awarded if <br /> the marquee exceeds the <br /> maximum height. <br /> 7. To ensure daylight pene- <br /> tration, the ratio of the <br /> marquee's projection from <br /> the building to its height <br /> above finished grade may <br /> not exceed 3:4. <br /> 8. Maximum horizontal projec- <br /> tion from building facade <br /> shall be 8 feet. <br />