Laserfiche WebLink
� . -� <br /> � <br /> I <br /> , <br /> � <br /> I <br /> CITY Ol' PV7:HP^P'i' I <br /> IIUTLDI\'G DLP11R'PNi;i:'.i <br /> pnl`L Pebruar�� 9, 1978 PliAN C012RliCTION ,S'.1i31;1' ' L%+U C'.'.^,: 1:0�����'2 <br /> OP]NLR Tiz ' s Door Sales USP Door Dlanufacturin3 <br /> CON'PR71C'1'OR ��•C. Gohl Construction USL 70NIi:U ' <br /> -- -- ------- - - � <br /> AI2CIIITIiCT Ivary/Tai�asinki Assoc. FIRli 'I,Ob?L 2 � <br /> JOI3 SITP•. AUDREuS 2118 38ti� Street OCCOPANCY GI?OUP E-2 , E-3 , F�-2 <br />� — --- — <br />� TYYE OP' CU`iSTitUCT7,�iJ IV"i Sprinkler OCC[7PI�NT LO%�D ;qZ _ _ <br /> In responsc to your applicati.on for a permit, your plans and speci.fir:ations, � <br /> have been e}:-.mine�z and you arc advised tl:at the issuance of a permi� is with- <br /> helci f:or the r.casons herei_nafter. set forth. tdOTi, CAI+.IsFULLY: Ans�t��:� uuestions <br /> aiid na}:e c:;planations HY COI:REt:TIi�7G ORIGINnl:� PL�ni1S , and neca plans ���bmitted <br /> to the Dep�rtr„ent of Building and In:pecticn. (TIIi.S SllELT C4US'P T3F t'LTURN3:D <br /> S4ITH ORIGINl`.L PLAivS AIQll SPPCIP1Ctl'i'IO\S OR T1IliY 49TLI., I3L FILGU AS NP:,S9 i3USliVii55) . <br /> N0. �— UN.l"POR1d I3UiLDIP]G COD� 1)7� I;D'_TION -- CODI SEC. <br /> �1. A one-hou.r fi.re-resistive occupancy separation is required Tabl.e 5-B <br /> � between the paiat i�ays and mai.n plant area and the offices� <br /> and main plant area. <br /> Y \2. Fxterior wall within 5 feet of propert}� lines (soutn �aall) �% Table 5-A <br /> shall be A hour fire-rated construction. �,� 2 J�v. c,,,�� <br /> <<'\�. Exterior wall on west side shall be or.e-hour fire-resistive��Tab].e 5-� <br /> � construct�_on. <br /> �,;� 4 . Openings in occupancy separations shall comply with Sec . <br /> sos c�) • ��. 5p� � �;v.�,, i,.� � �_%� �� I�- <br /> . � <br /> MIL 5 . Nonabsorbent backinq and finisl: for toilet room walls shall <br /> comply �aitn Sec. 1'11 ;a) . -i-�, �y z,,,,�, �z;,S�Gs-r- <br /> '�-•='-��i Two exits are required fror.m serond floor office area and 3302 (a) <br /> ;i mezzanine. Ex�ts shall be seoarated a minimum of one-half 3302 (c) <br /> St: � :. : the diagonal o� the are a served. <br /> �I1/�i�i)L,�:L'� /. <br /> �,�.��7 . Han@rails shall be placed between 30" and 34" abcve the nos 3305 (i) <br /> of che stair t.read. <br /> -� . The enclosed usable space under the office area stairway 3305 (1 . ) � <br /> shall Ue protected on the enclosed side as reRuired for <br /> one-hour fire-resistiva_ constru^£ion. <br /> �'9� 9. Dracoing shall indicate how toilet rooms comp'.� with <br /> I "Requlations for Barrier - Pree Facilities. " (See attached <br />� code sections) . <br /> / <br /> . -__ n�\G;; 1 OF 2 (., <br /> � <br />� <br /> y.� <br /> II <br /> r <br /> I <br />�.e �-; . <br />