My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1300 44TH ST SE 2016-01-01 MF Import
>
Address Records
>
44TH ST SE
>
1300
>
1300 44TH ST SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2017 12:49:21 PM
Creation date
3/31/2017 12:49:03 PM
Metadata
Fields
Template:
Address Document
Street Name
44TH ST SE
Street Number
1300
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> Botesch, Nash & Hali Architects, P.S. � <br /> March 16, 1995 <br /> o t� � C� � d � D <br /> nnr. �eff�ey s. nncFau MAR 1 71995 <br /> Associate Engineer/Building ..,.,, <br /> City of Everett Building Division "'""",'.,^�.. . .,,,.. <br /> 3200 CedarSt CITY�OF BV�ReTT <br /> Everett, WA 98201 B�dB• Pa►mit CAunt�r <br /> Re: Owner: Cornerstone Prosthetics <br /> Job Address: 1300 - 44th St SE <br /> Plan Check Nurnber: B-47043 <br /> Job No. 1036 <br /> Dear Mr. McFall: <br /> Attached are two complete nev+r sets of drawings per the project noted above <br /> providing the corrections requested in your letter dated March 7, 1995. <br /> Noted below are responses according to the reasons for the issuance of the perrnit <br /> to be withheld. All corrections are on the drawings and assigned Revisior No. 2, <br /> dated March 10, 1995. <br /> 1 . Structural calculations are provided - see attached. <br /> 2. Lighting power allowance calculations for interior and exterior lighting are <br /> provided on Sheet A-2. <br /> 3. A note specifying that downspouts must be tightlined to the storm sewer is <br /> located on Sheet A-2. <br /> 4. The mechanical platform framing and seismic bracing is provided as Detail No. <br /> 2 on Sheet A-1. <br /> 5. The suspended ceiling seismic bracing is provided as Detail No. 4 on Sheet A- <br /> 3. <br /> 6. The grab bars, seat and ad1'ustable shower head are noted in the accessible <br /> showerlocated on Sheet A-3. <br /> 7. The "U" values for glazing, doors and wall insulation are provided on Sheet A- <br /> 5. <br /> 8. Attic ventilation calculations including make-up for the HVAC equipment are <br /> provided on Sheet A-1 . <br /> 4206 Hoyt Avenue • Everett, Washington 98203 • 206/259-0868 • 206/774-3341 • fAX 206/252-4334 <br /> ^s�: M�Ly� :" . _ . � � � <br /> 4 '` li: <br /> h0. F <br /> .. -- -- . Y .. .�'i... .�.��' . . . . . . . �F., :i <br />
The URL can be used to link to this page
Your browser does not support the video tag.