CONSTRUCTION <br /> 1. The new interior stair plan should indicate new wall constructio��,where applicable, with wall sections to <br /> ��� �� indicate materials. <br /> �����v� a. Please see Detail A, Sheet 54 of 4. <br /> S'�� <br /> ,K`�2. The vertical separation between the three residential units should 6e referenced on the drawings to wa <br /> � sections indicating tested wa�l assemblies to meet the requirements of one hour fire resistant partitions, per IBC <br /> sections 420.2, 709.3,and the continuity requirements of IBC section 709.4. <br /> a. Plea;�see sheet S3 of 4 Building Cross-Section and details A, B &C. <br /> 3. The horizontal separetion between Units A and B should be referenced on the drewings to floor sectiuns <br /> indicating tested floor assemblies to meet the requirements of one nour fire resistant horizental assemblies, per <br /> IBC sections 420.3 and 712, anu the continuity requirements of I8C section 712.4. <br /> a. Please see sheet 53 of 4 Building Cross-Section and details A, 4 &C. <br /> 4. The garage should be marked on the floor plans. <br /> a. Please see Sheet 53 of 4. <br /> EGRE55 <br /> 1. The new interior stair treads and risers should be dimensioned on the drawings as minimurti 11 inch tread, and <br /> maximum 7 inch riser, per IBC section 1009.4.2. <br /> a. Please see clouded notations on sheet 53, stair detail. <br /> 2. Continuous handrails should be shown on the drawings on one side of the new interior stair, per IBC section <br /> 1009.12,exceptian 2. The handraif should be shawn to extend from the top riser to the bottom riser, per IBC <br /> section 1012.6, exception 1. <br /> a. Please see sheet 53, stair detail. <br /> 3. The profile of the interior stair handrail should be shown or. ttie drawings to meet the graspability of Type 1 <br /> handreils, per IBC section 10123.1. <br /> a. Please see sheet S3, stair detail, 1 %:"-2" continuous rail notation. I <br /> 4. Each bedroom should indicate an emergency escape and rescue window opening, mee[ing the requirements of <br /> IBC section 1029.1,with a reference to an elevation of the window meeting the requirements of IBC section <br /> 1029.2. <br /> a. Please �e�erence clouded notation on bottom of sheet 52. All forms of egress have been dimensioned <br /> and labeled (unclouded for legibility). <br /> 5. Single or multiple-station smoke alarms should be shown on the drawings on the ceiling or wall outside of each <br /> separate sleeping area in the immediate vicinity of bedrooms, in each room used for sleeping purposes,and in <br /> each story within a dwelling unit, per IBC section 907.2.1:3. Currently shown as having the same symbol as a <br /> fan. <br /> a. Symbols for fire alarms have been corrected on Sheet 52 of 4. <br /> 6. Note: this will require an electrical permit application. <br /> a. Noted. Electrical contrector is aware of their permit requirements and will seek a separate electrical <br /> permit. <br /> 2 <br /> ._ . . . . .. �n: <br />