Laserfiche WebLink
�rv�rotv ' �ittact�nnent C <br /> J�����/ <br /> G.[�7M■ <br /> �� Plans Examiner and In e�tor Checkli�t <br /> sp <br /> Pertnit No. J� I � � Address 5 � .5 — y'�71� ST <br /> Plans Examiner: Check, write in N/A, or fill in value on shaded boxes. <br /> Inspector: Check oH boxes at lefl as items are(ound to comply. <br /> Compliance approach: (check one) ❑Systems analysis ❑Component per(ormance IJ Prescriptive path <br /> Note: Some specifics on this form may not apply if <br /> A) compliance approach is systems analysis or component performance; <br /> B) compliance to minimum ventilation criteria is demonstrated through engineering caiculaiions or perfomiance testing. <br /> FOUNDATION PHASE �„ <br /> ❑ Sleb: ��Extarlor down to frostllne/slab bottom;or Interlor 24"horizontai or vertical;or,11 radlant, under entlre slab <br /> ❑ Below grede exterlor well Insulatlon: �� Qf Interlor—see Insulatlon Phase) <br /> ❑ Redon millgetlon:�II locally requlred,or crawlspace venting<1fV3DOft2 ot crawl,or vents include an operable damper <br /> FR►1MING PHASE <br /> ❑ Freming: �Standard �Inlermedlate u Advanced <br /> ❑ Std alr�eel:soiepUsubllr;rim JsUmud�III;wlndow&door frms;penetratlon-wlre,plumb,duct, partitlon studs,flue, Ilght fl#ures <br /> ❑ Source apeclflc exhaust}ans: Size requlremenl—balh,laundry(50c1m);kllchen(100cfm) <br /> ❑ Whole house exfieust len ���pfrr, Intermirient system has manual&auto controls;Outdoor alr supply raq.for hebltable rms. <br /> or <br /> ❑ Inlegrated forced-elr system �A� outslde aly duct(wilh dampar)allowing behvsen.35 and.5 ACH <br /> INSULAT�N PHASE _ <br /> ❑ __���� WeIllneuietlon(ebovegrade) R-�3 � ��S7�G ��f Co/JST, <br /> ❑ �_—1�A� Wall Insuletlon(below grode):Interlor wall Insulatlon <br /> ❑ '�j.,��� � Floorinsuletlon <br /> ❑ �� Ceiling Ineulatlon:Including atllc hatch <br /> ❑ �j�� Veulted celling Insuletlon <br /> ❑ Vepor rctarders:wa�ls,lloors,celling <br /> �----�..__.... <br /> ❑ Honting systam type: �G�^�' e„ For heatpumps, Ilst size, HSPF,and COP ; . <br /> Itr.' �.._:_ �------__.._.::�. <br /> FINAL PNASE <br /> ❑ Rodon monitor on site:wlth Instructlons and general Inlormatlon <br /> ❑ Thermostat: heat range,55-75;AC range, 70-85;both, 55-85.Backup heat controls prevent slmulteneous operatlon of prlmary sys. <br /> ❑ Solld fuel nppllonces:glass or metal doors;dlred comb.aIr source,or 4"dla.,dampered,Indlrect source lor uncond,areas <br /> ❑ Flrepleces:6"combustlon alr supply duct w/damper dlrecl to 1lrebox;tight titting glass or metal doors. <br /> ❑ DHW heaters:NAECA label;separate power or gas shut-oti;on A-10 pad II electrlc and In uncond.area orN on concrete <br /> ❑ Mechenlcel venillatlon ducts Insuleted to R-4:exhaust duds In uncondilloned areas/suppiy ducls In condltioned areas <br /> ❑ �_���4 _] HVAC ducts/plenum Insuletlon:ducts In uncondltloned areas are Insulated and Jolnts are sealed <br /> ❑ Plpe Insulntion: R-31or hot and cold water plping In uncondltloned areas(It servlce or redreulating,see Table 5-12) <br /> ❑ C3round cover:6 mll biack polyethylene/approved equal pped 12"at Jolnts and extending to toundatlon wall <br /> a.w�a�.�n.rr... . . . . _ _ . ..r—:- - . - . . <br />