Laserfiche WebLink
' Washington State Energy�ode: Component Pertormance Work�ieet <br /> Zone 1, Other Fuels <br /> Walls(Above Grade) <br /> Plan Component Wall <br /> ID Description Ref. U Area UA <br /> R21 caviry+RO foam INT 2X6W Lap � 10•5 0.054 947.0 51.1 <br /> rt15 caviry+tt0 foam STD 2x4W Lap � 10-5 0.076 133.0 10.1 <br /> � 0 0.000 0.0 <br /> � 0 O.00G 0.0 <br /> Sum of Area and UA 1080.0 61.2 <br /> Floor(over crawl or exterior) <br /> Plan Component Floor <br /> ID Description Ref. U Area UA <br /> � 0 0.000 0.0 <br /> � 0 0.000 0.0 <br /> � 0 0.000 0.0 <br /> � 0 0.000 0.0 <br /> Sum of Area and UA 0.0 0.0 <br /> Slab on Grade(less then 2 feet below grade) <br /> Flan Component Slab Slab <br /> ID Description Ref. F Len th UA <br /> RIO 2'honzontal w/TB � WSU 0.540 70.0 37.8 <br /> � 0 0.000 0.0 <br /> � 0 0.000 �.0 <br /> � 0 0.000 0.0 <br /> Sum of Area and UA 70.0 37.8 <br /> CopyrgM 2002, WSUCEEP 02•049(Version 2) <br /> Copied by permission trom Washington State University Cooperative Extension Energy Program. <br /> (see copyright restrictions) <br /> 9/16/2003 4 of 6 <br />