Laserfiche WebLink
INSULATION CERTIFICATION <br /> (THIS CARD IS TO REMAIN PERMANENTLY POSTED IN A READtLY ACCESSIBLE LOCATION) <br /> THIS IS TO CERTIFY THAT IN CONFORMANCE WITH THE CURRENT THERMAL PERFORMANCE STANDARDS <br /> WASHINGTON STATE ENERGY CODE, CHAP. 51•12 WAC, REVISED 1986,AND APPROVED PLANS, I HAVE INSPEC- <br /> TED THE ENERGY PACKAGE AND CERTIFY THAT IT HAS BEEN INSTALLED IN ACCORDANCE WITH THOSE <br /> STANDARDS IN THE BUILDING LOCATED AT: � <br /> 150749TH PL SW EVERETT WA � <br /> PAar.ss W ProWNy �( n . , <br /> DESCP�TION OF INS7ALLATION <br /> ROOFS <br /> Type of Material Manuh rer Thickness R Value <br /> (Or trade naPie) <br /> EXTERIOR WALLS <br /> Type of Materlal F�ba��-- - � .lMnutechiror�OFINS MANVILLE Try����s 3/6 R Vdue 13��9 <br /> (d trade n�- — <br /> CEILINGS ' <br /> BATTS: <br /> Type of Mate�ial Fiberglass Manuhcwrer�OHNS MANVILLE 6/10 19/30 <br /> Thlelmess _ R Yelue <br /> (Or trade name) <br /> 180/25 Sq.Ft.Covered . <br /> BLOWN: � ) ��\ ) � � <br /> �e,af�Materiel�j�` /�' �� Manuhcturer j�_ Thickness f.,,L_ No.B� <br /> Wt/Dag 958 Sq. FI.Covered 30 R Velue <br /> FLOORS <br /> Type of Material Fiberglass Manufaeturor 10HNS MANVILLE �g <br /> Thickn� � R Value <br /> (or 61�d�nunN <br /> SLAB ON GRADE ' j. � ��� � <br /> Type of Material M�nu� �e�s R VaAr'�� <br /> (Or Ir�. <br /> Wdlh of Insulation MchN <br /> FOUNDATION WALLS(if required) <br /> Type of Material r Thiekneea Il VWIe � <br /> («�e) <br /> DUCT ANDIOR PIPE INSULATION <br /> Type oi Material Manufaeturer Thickness R Value <br /> (Ortradename) <br /> HEATING SYSTEM <br /> TypeofSystem Manufacturer ___ Input Oulput __ ___ <br /> ❑ NIGHT SETBACK THERMOSTAT INSTALLED <br /> ❑ HEATING SYSTEM INSTALLED TO NO MORE THAN 160% OF DESIGN LOAD WASHINGTON INSULATION INC. <br /> ❑ GLAZING—ALL GLAZING INSULATED GLASS OR STORM WINDOWS PROVIDED 16120 WOODINVILLE REDMOND R0.N.E. <br /> ❑ WATER HEATERS—ASHRAE 90A-80 LABELED SUITE IS <br /> ❑ WATER FLOW RESTRICTORS—ALL SHOWERS LIMITED TO 3 GPM WOODINVILLE,WA-7 2 <br /> ❑ INFI LTRATION—DOORS 8 WiN DOWS WEATHERSTRIPPED OR APPROVED BY ASTM 283-7 3 <br /> ❑ INFILTRATION—ALL OPENINGS IN EXTERIOR WALLS CAULKED OR SEALED <br /> ❑ FIREPLACES—OUTSIDE AIR VENT(SIX SQUARE INCHES)WITH DAMPER TO FIREBOX <br /> ❑ SLAB THERMAL BREAK CREATED <br /> ❑ VAPOR BARRIERS—INSTALLED PER CODE �� <br /> REMARKS (if desired) <br /> I CERTIFY UNDER PENALTY OF FERJURY UNDER THE LAWS OFTHE STATE OF WASHINGTON THAT THE FOREGOING IS <br /> TRUE AND CORRECT. Contractor's Reg. No. <br /> General Contractor(Builder) <br /> By Title <br /> Daie and Place <br /> Sub-contractor(Insulation Applicator) WASHINGTON INSULATION Contractor's Reg. No. WASH-III-134M3 <br /> B (Insulation, Masonry,elc.)(State"SAME"if same as General Contractor) <br /> y Robert M lurgenson '^ <br /> �,�— Tille Operations Manager <br /> Date and Place 7�Zg�9g � � <br />