Laserfiche WebLink
4. <br />5. <br />6. <br />PUBLIC WORKS PERMIT COMMENTS <br />Connect side sewer per Ciry Standard #601. <br />Connect side sewer per Ciry Standard #'s 601, 602, 604. <br />Connect all rooftop downspouts to the side sewer. <br />Connect rooftop downspouts to the drainage system provided for this lot. <br />/ 8. � Rooftop runoff must be discharged to a roof downspout infillration system per Cily of Everett Storm <br />L/ Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />C/ The contrector must meet with the Public W orks Inspector to discuss potenlial drainage routing prior to <br />� beginning the project. <br />10 Install ei _ion r,ontrol measures as delermined by the Public Works inspector, such as sill fence, straw <br />bales, swales, or erosion blankets. <br />11. Install erosion control measures per Cily of Everett Standards for small parcels <br />16. <br />Remove erosion control measures upon completion of the project prior to final approval of lhe permit. <br />All excavated material from foundation, sidewalk and driveways shall be hauled to an approved. <br />permitted site. No wasting of malerial is allowed on this building bt. <br />No dirt, mud, rocks or debris to be tracked onto roadway. <br />No building materials lo be stacked on sidewalks and sidewalks to be kepl clean and open for <br />pedestrian travel. <br />Adjust water meter box 1" above sicewalk grade. <br />17. Remove and replace curb, guller and sidewalk as per City of Everett Standard Plan #'s 305A & 306 on <br />this proposal's fronlage as directed by the Public Works Inspeclor (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />18. <br />79. <br />20. <br />21. <br />22. <br />Inslall a Type I concrete driveway per Cily of Everelt Slandard #307. <br />Pave driveway from the front property line out to the street paving. <br />Contact the Water District for connecting provisions for this building's water and <br />sewer services. <br />A catch basin as per City Standard Plan tl402 with a gas trap per Standard Plan #410 is required for the <br />parking area. <br />If a sewer pump system is to be installed, the pressure line must discharge into a private manhoie, then <br />grevily flow across the public right-of-way. <br />23. A sprinkler system is required for lhis building in compliance with the requirements of NFDA Standards <br />13D. <br />i <br />PN'Comments � ' � <br />�/ <br />