Laserfiche WebLink
G. Premise Identificution - Premises shall be clearly idenTified by the :orrect address at the <br /> street en[r}�. Buildings shail be clearly identified so as to be visible and leeible from the <br /> access roa1. Individual apartments and suites, �i�here applicnble, shall be olzarly and <br /> legibly identified from the access road. <br /> 7. P'ire 1-Ivdrants - Locatior.s as planned are acceptable. <br /> 8. PRGbI1SE IDEIv`T[F:C:�TIOi� AND ALL RGQUIRLD FIRE llEPARTD7GNT <br /> ACCGSS ROADS AND FIIiE 1:YDRANTS SHaLL BG IN SERVICE PRIOR TO <br /> COMMGNCG�,MGNT OF CONST2UCTION. � � <br /> 9. Based upon i0,953 square feet of Type fIl-B, sprinklered construction, the fire flo�v <br /> requirement is 2,37� gpm. This will increase if a mezzanine is added. <br /> 10. Portable Pire Protection - A portable fire estinguisher witlt a miuimum U.L. rating of <br /> 2-A:10-B;C shall be provided within 7� feet of travel on all floors of eacli building <br /> during construclion and prior to occupancy. <br /> 1 I. Fire AI1rm Svstem - An approved automatic fire detec[ion system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. <br /> ('lans lor sucf� system sh�dl Uc submitted to the �ire Marshal for review and approval <br /> prior to installation. Submittal shall include cut sheets of all equipment intended for use. <br /> Appropriate trip tests, witnessed by a �ire Department inspector, shall be performed, <br /> �long widi a certilicate of completion, prior to final acceptance of the system. <br /> Fire .ilarm systen�s shall be ins[alled according to NFPA Standard 72. Instullatiun of <br /> tire alarm components, including basic �viring, may not commence bcfore plans arc <br /> :ippruvcd by the rire Dep:vhnent Plan Revic��•er. Fire alarm drawings must be <br /> professionally rendered, in sufficient detail, and must be intemally consistent. Riser <br /> diaerams must match installation plans and load calculations. Components must be listed <br /> and appro��ed for use together. Changes to plans must include new dra�vings and <br /> calculations and must be approaed by the Fire Department Pfan Reviewer priur to <br /> ' installation. ['ire alarm ir.stallation is subject to tield inspection by a Fire Department <br /> Inspector. An appro�ed set of plans and the Building Department electrical permit must <br /> be present for any installation inspection. <br /> Fire alarm svstems shall be installed under permit oC the Ciry of Everett Building <br /> Department. Electrical inspections and appro��nl are required prior to calling for <br /> �icceptance tests. Call (42>) 2�7-SS10 for pemlit information. <br /> The abscncc of���urf:ing phonc lines for the ularm system will be cause for <br /> post�uning tire departmcnt inspection and testing and shall result in denial of <br /> occupanc�'. <br /> , <br /> 1 <br /> � �l <br /> J6 /./ <br />