2006 Washington State Nonresidential Energy Code Compiiance Form
<br /> • � � • .
<br /> , 2GW Was���tcn Slam Nonreatlenoal Energy Cotle Compbance Fortns � RevisaE July YOOi
<br /> Prescriptive Spaces Occupancy: � Warehouses,storage areas or aircraft storage hangers QOther
<br /> Qualification Checklist Lighting � Check if 95%or more of fixtures comply with 1,2 or 3 and rest are ballasted.
<br /> No�e.II occuDanry rype is"Othet'anC(zture Fi%�UreS:
<br /> answer is cnecked,the numuer or f�nures in (Section 1. Fluorescent fixtures which are non-lensed with a) 1 or 2 rivo lamps,b)reflector
<br /> the:pace is not limitea Dy COUe. Clearly 1521) or louvers,c)5-60 watt T-1,T•2,T4,T•5,T-8 lamps,and d)hard-wired elec-
<br /> inaicate tnese spares on pians. Irnoi tronic dimming ballasts. Screw-in compact fluorescent fi�Aures do not qualify.
<br /> quaiir�ea,do LPA Calcuiatians. 2, Metal Halide with a)reflector b)ceramic MH lamps<= 750w c)electronic oallasts
<br /> 3. LED lights.
<br /> TABLE 15-1 Unit Li htin Power Allowance LPA
<br /> Use LPA W/s Use LPA Wls
<br /> Automotive facility 0.9 OKce buildings,office/administrative areas in 1.0
<br /> facilities of other use types(including bul not limited
<br /> to schcols,hospitals,institutions,museums,banks,
<br /> chumhes`�`�"
<br /> Convenlion center 72 Penitentiary and other Group I-3 Occu ancies 1.0
<br /> Coudhouse 12 Police and fre stations° 1.0
<br /> Cafeterias,fast food establishments , 1.3 Post oKce 7.1
<br /> restaurants/bars'
<br /> Dormimry 7.0 Retail , retail bank�ing. mall concourses,wholesale 1.5
<br /> stores(pallet rack stelving)
<br /> Exercise center 1.0 School buildings(Group E Occupancy only),schoal 12
<br /> classrooms,da care centers
<br /> G mnasia ,assemh� I s ace� 1.0 Theater,motion icture 1.2
<br /> Health care clinic 1.0 Theater, erformin arts t.6
<br /> Hospital,nursing homes,and oiher Group I-1 and 12 Transpoeation 7.0
<br /> I-7 Occuoancies
<br /> Hotel/motel 7.0 Warehouses ,stora e areas 0.5
<br /> Hctel banqueVcon!=r=nc-!ex`:�tiun hall - 2.0 Worksho s 7.4
<br /> Laboiatory spaces(all spaces m�t classified 1 8 Parking garages 0.2
<br /> "laborator;"e!±_!!mec;oh�ce and other appropriate
<br /> cate ories)
<br /> Leundries 12
<br /> Libraries;- 1.3 Plans Submitted(or Common Areas 7n1�!
<br /> Manufacturin facilit 1.3 Main Floor buildin lobbies exce t mall concourses 1.2
<br /> Museum 1.1 Common areas,cnrridors,toilet(acilities and 0.8
<br /> washrooms.elevator lobbies
<br /> Footnotes for Table 15-1
<br /> 1) In cases in which a general use and a specific use are listed the specific use shall apply. In cases in which a use is not meniioned
<br /> specifwlly,tha Unit Power Allowance shall be determi�ed by ihe building oKcial.This aetermination shall be based upon the most
<br /> comparable use specified in the table. See Section 1572 for exempt are;s.
<br /> 2) The watls per square foot may be'ncreased,by hvo percent per(oot o�ceiling height above iwenty feel,unless specifically directed
<br /> otherwise by subsequenlfootnotes.
<br /> 3) Watls per square foot of room may be increased by two percent per foot o(ceiling height above twelve feet.
<br /> 4) For all other spaces,such as seating and common areas, use the Unit Light Power Allowance for assembly.
<br /> 5) Watts per sGuare foot of room may be increased by two percent per foot ci ceiling height above nine feet.
<br /> 6) Reserved.
<br /> 7) For conference rooms ard offices less Ihan 150R' with tull height padilicns,a 7nit Lighting Power Allowance of 1.10 wlft�may be used.
<br /> 8) Reserved.
<br /> 9) For indoor sport toumament courts with adjacent spectamr seating over S,OGO,the Unit Lighfing PowerAll�wance for the ccurt area is
<br /> 2.60 W/R'.
<br /> 10) Display window illumination installed within 2 feet of the window,provided that the display window is separated from the retail space by
<br /> walls or at least Ihree-quarter-height partitions(transparent or opaque).and lightiug for free-standing display where Ihe lighting moves
<br /> with ihe display are exempt.
<br /> An�dditional LS wlft'af inerchandise display luminaires are exempt provided that they comply with all three of the following:
<br /> a) located on ceiling-mounfed lrack or directly on or recessed into the ceiling ilself(not on the wall).
<br /> b) atljustable in both the horizontal and vertical axes(vetl�cal axis only is acceptable for fluorescent and other fa1ures with lwo points
<br /> of track attachmenl).
<br /> c.) fitted with LED.tungsten halogen,tluorescent,or high intensity discharge lamps.
<br /> This additional lighting power is allowed c,nly if the lighting is actually installed.
<br /> 11) Provided that a Iloor plan,mdicating rack location and height,is submitted,the square footage for a warehouse may be defined,for
<br /> computing lhe interior Unil Lighting Power Allowance, as the Ooor area not covered by racks nlus the veAical face area(access side anly)
<br /> of the racks.i he height allowance defned in foolnote 2 applies onty to the Aoor area not covered by racks.
<br /> 2,�
<br />
|