2006 Wash�^qton State Nonresidential Ener y Code Compliance Form
<br /> • • • • .
<br /> 2006 Waslmgton Slale Nonreaqenliel Enerqy Cotla Complianca Forma ReviseE July 2007
<br /> Prescriptive Spaces Occupancy: � Warehouses,storage areas or aircraft storage hangers Q Other
<br /> Qualification Checklist Lighting � Check if 95%or more of fixtures comply with 1,2 or 3 and rest a2 ballasted.
<br /> Note:II acupancy rype is"Othef'ana fizture Fixtures:
<br /> answer is checke4 me numoer ol r,nures in (Section 1. Fluorescent fixtures which are non-lensed with a) 1 or 2 two lamps,b)reflector
<br /> me space is not iimited by Code. Ciearry 1521) or louvers,c)5-60 watt T 1,T•2,T-0,T•5,T-8 lam�s,and d)hard-wired elec-
<br /> intlira�e tnese spaces on pians. II not tronic dimming ballasts. Screw-in compact fluorescent fizlures do not qualily.
<br /> quaiifed,ao LPA Caiculations. 2.Metal Halide with a)reflector b)ceramic MH lam�s<= 150w c)electronic ballasts
<br /> 3.LED lighls.
<br /> TABLE 15-1 Unit Li htin Power AlloHrance LPA
<br /> Use LPA W/s Use LPA /s
<br /> Automotive facility 0.9 Office buildings,oKce/administrative areas in 1.0
<br /> facililies of other use types(including but not limited
<br /> to schools,hospitals,institutions,museums, banks,
<br /> churches""
<br /> Convention center 7.2 Penitentia and olher Grou I-3 Occu ancies 1.0
<br /> Courthouse 12 Police and fire stations 1.0
<br /> Cafeterias,fast(ood establishments , 1.3 Post oKce 1.1
<br /> restaurantslbars'
<br /> Dortnitory 1.0 R-� ,r° etail banking, mall concourses,wholesale 7.5
<br /> stores( allet rack shelvin
<br /> Exercise center 1.0 School buildings(Group E Occupancy only),school 1.2
<br /> classrooms,da care centers
<br /> G mnasia ,assembl s aces 1.0 Theater,motion icture 1.2
<br /> Health care clinic 1.0 Theater, erforming arts 1.6
<br /> Hospital, nursing homes,and other Group I•1 and 12 Transportation 1.0
<br /> I-2 Occu ancies
<br /> Hotel/motel 1.0 Warehouses ,store e areas 0.5
<br /> Hotel ban ueUconterence/exhibition hall � 2.0 Worksho s 1.4
<br /> Laboralory spaces(all spaces not classified 7.6 Parking garages 02
<br /> "laboratory"shall meet oftice and other appropriate
<br /> wte ories)
<br /> Laundries 7.2
<br /> Libraries 1.3 Plans Submitted for�ommon Areas Onl
<br /> Manufacturin facilit 1.3 Main floor buildin lobbies exce t mall concourses 1.2
<br /> Museum 1.1 Common areas,wrridors,toilet facilities and 0.8
<br /> washrooms,elevator lobbies
<br /> Footnotes for Table 15-1
<br /> 7) In cases in which a general use and a specific use are listed,the specific use shall apply. In cases in which a use is not mentioned
<br /> specifically,the Unit Power Allowance shall be determined by the building offcial.This determination shall be based upon the most
<br /> comparable use specified in the table.See Seclion 1512(or exempt areas.
<br /> 2) 7he watts per square foot may be increased,by two percent per foot of ceiling height above twenty feet,unless specifically diredeG
<br /> othenvise by subsequent footnotes.
<br /> 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
<br /> 4) For all other spaces,such as seating and common areas,use the Unit Light Power Allowance for assembly.
<br /> 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
<br /> 6) Reserved.
<br /> 7) For conference rooms and oKces less ihan 150ft� wilh full heighl padilions,a Unit lightinq Power Allowance of 1.10 w/k'may be used.
<br /> 8) Reserved.
<br /> 9) For indoor spoA toumament courts with adjacent spectator seatin9 over 5,000,the Unit Lighting PowerAllowance for the court area is
<br /> 2.60 W/Ft'.
<br /> 10) Display window illumination installed within 2 feet of ihe window, provided that the display window is separated from the retail space by
<br /> walls or at least Ihree-quarter-heighl partilions(transparent or opaque). and lighting for free-standing display where the lighting moves
<br /> with the display are exempl.
<br /> An additional 1.5 wlfl'of inerchandise display luminaires are exempt provided thal they comply with all ihree of the following:
<br /> a) located on ceiling-mounled track or directly on or recessed into ihe ceiling itself(not on the walp.
<br /> 6) adjustable in both Ihe horizontal and vertical axes(vehical axis only is acceptable for fluorescent and other fixtures with two points
<br /> of track attachment).
<br /> c) fltted with LED,tungsten halogen,Fluorescent, or high intensity discharge lamps.
<br /> This additional lighting power is allowed only if the lighting is aclually installed.
<br /> 11) Provided that a floor plan, indicating rack localion and height,is submitted,the square foolage tor a warehouse may be defined,for
<br /> computing the interior Unit Lighting Power Allowance,as the Floor area not covered by racks plus the vertical face area(access side only)
<br /> of ihe racks.The height allowance defined in footnote 2 applies only to the tloor area not covered by racks.
<br /> ��j�