2006 Washington State Nonresidential Energy Code Compliance Form
<br /> • • • • .
<br /> 2006 N'ashuqton Slate Nonres�amtial Enerqy COCe Carpliarre Fams ReNxE Juy 2007
<br /> Prescriptive Spaces occupancy: � Warehouses,starage areas or aircraft storage hangers �Other
<br /> Qualification Checklist Lighting � Check H 95°/a or more of fictures comply witn 1,2 or 3 and rest are ballasted.
<br /> Note:II occupanq rype is"ONef'antl fiature Fixtures:
<br /> answer is cneckea,Ue number of fi�nures in (Sedion 1. FluoresceM fiztures which are non-lensed wilh a) t or 2 two lamps,b)retledor
<br /> the space is not iimiteG by CaGe. Geany 1521) or louvers,c)5-60 watt T-7,T-2,T-4,T-5,T-8 lamps,and d)hard-wired elec-
<br /> ind�care tnese sDaces on plans. If no� tronic dimming ballasts. Screw-in compad fluorescent fixtures do not qualify.
<br /> quaiifiea,do LPA Calcuiations. 2.Metal Halide with a)reflector b)ceremic MH lamps�=150w c)electronic bal;asts
<br /> 3.LED lights.
<br /> TABLE 15-1 Unit Ll htin Power Aliowance LPA
<br /> Use LPA W/s Use �PA W/s
<br /> Automotive(aciliry 0.9 OKce buildings,office/administrative areas in 1.0 �
<br /> facilities of other use rypes(including but not limited
<br /> to schools,hospitals,institutions,museums,banks,
<br /> churches"•"
<br /> Convention center 12 Penitentia and other Grou 13 Occu ar.cies 1.0
<br /> CouAhouse 12 Police and fire stations 1.0
<br /> Cafeterias,fast food establishments , 1.3 Post office 1.1
<br /> restaurants/bars'
<br /> Dormitory 1.0 Relail , retail banking,mall concourses,wholesale 1.5
<br /> stores allet reck shelvin
<br /> Exercise center 1.0 School buildings(Group E Occupancy only),school 1.2
<br /> classrooms,da wre centers
<br /> G mnasia ,assembl s aces 1.0 Theater,motion icture 1.2
<br /> Health care clinic 1.0 7heater, riormin arts 1.6
<br /> Hospital,nursin9 homes,and otlier Group I-7 and 12 TrenspoAation 1.0
<br /> I-2 Occu ancies
<br /> Hotel/motel 7.0 Warehouses ,stora e areas 0.5
<br /> Hotel ban ueUconferencelexhi6ition hall � 2.0 Worksho s 1.4
<br /> Laboratory spaces(all spaces not classified 7.8 Parking garn�es 0.2
<br /> "laboratory'shall meet oKce and other appropriate
<br /> wte ories
<br /> Laundries 1.2
<br /> Libraries 1.3 Plans Suhmitted tor Common Areas Onl
<br /> Manufacturin facilit 1.3 Main floor buildin lobbies exce t mall concaurses 1.2
<br /> I Museum 1.1 Common areas,corridors,toilet facilities and 0.9
<br /> washrooms,elevator lobbies
<br /> Footnotes for Table 15-1
<br /> 1) In cases in which a general use and a specific use are listed,the specific use shall apply. In cases in which a use is not mentioned
<br /> specifically,the Unit Power Allowance shall be determined by the building oKcial.This determination shall be based upon the most
<br /> comparable use specifed in the table. See Section 1512 for exempt areas.
<br /> 2) The watts per square toot may be increased,by iwo percent per foot of ceiling height above twenty feet,unless specifically direded
<br /> otherwise by subsequentfootnotes.
<br /> 3) Watts per square foot of room may be increased by lwo percent per(oot of ceiling height above lwelve feet.
<br /> 4) For all other spaces,such as seating and common areas,use the Unit Light Power Allowance for assemb�y.
<br /> 5) Watts per square foot of room may be increased by lwo percent per foot of ceiling hei9ht above nine feet.
<br /> 6) Reserved.
<br /> 7) For conference rooms and oKces less than 150R� with full height partitions,a Unit Lighting Power Allowance of 1.10 wlft�may be used.
<br /> 8) Reserved.
<br /> 9) For indoor sport tournament courts wilh adjacent spedator seating over 5,000,the Unit(ighting Power Allowance for the court area is
<br /> 2.60 W!ft'.
<br /> 10) Display window illuminalion installed within 2 feet of the window,provided that the display window is separated from the retail space by
<br /> walls or al least three-quarter•height partitions(transparent or opaque).and lightin9 for free-standing display where the lighting moves
<br /> with Ihe display are exempt.
<br /> An additional 1.5 w/k'of inerchandise display luminaires are exempt provided that they comoly with all three of the following:
<br /> a) localed on ceiling-mounted track or directly on or recessed into the ceiling itself(not on the wall?.
<br /> b) adjustable in both the horizontal and vertical axes(vertical axis only is acGptable for Auorescent and other fixtures r�ith lwo points
<br /> o(track attachmenU.
<br /> c) fitted with LED,tungsten halogen,fluorescent,or high intenslty discharge lamps.
<br /> This additional lighting power is allowed only if the lighting is actually inslalled.
<br /> 11) Provi�ed that a tloor plan, indicating rack location anA height, is s��bmitted,the square footage f�r a warehouse may be defined,for
<br /> computing the interior Unit L;9hting Power Allowance,as lhe floor;rea not covered by racks plus the vetlical face area(access side oniy) ��
<br /> of the racks.The height allowance defned in footnote 2 applies only lo the flocr area not r,overed by racks.
<br /> 1
<br /> �/