My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6003 23RD DR W 2018-01-01 MF Import
>
Address Records
>
23RD DR W
>
6003
>
6003 23RD DR W 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2019 10:03:30 AM
Creation date
4/1/2017 10:13:13 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
6003
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
flEC-15-2006 FR1 11�30 AM T0� ";MT FAR N0, 5036203935 P, 02 <br /> Ltr. B0611-013 <br /> December I1, 2006 <br /> Page 2 <br /> LIFF.SAFETY <br /> i. 'Che first floor conference room occupant load is miscalculated in thc code data <br /> (Sheet AOA2). 1837 = 7 = 262. Please correct. <br /> Assuming the sliding room divider door is closed, each newly formed <br /> conference room would be requirc�i to have two exits (IBC 101�.1). Ali of Qic <br /> exit doors wouid bc required to comply with the arrangement requiremenis of <br /> ' iBC 1014.2.1, door swing requirements of IBC 1008.1.2, (including the <br /> vestibule) and panic hardware requirements of IBC 1008.1.9. Panic hardware <br /> would also be required at the vestibule and main building exit doors, Aiso, the <br /> room/rooms are required to be posted in accordance with IBC 1004.3. <br /> 2. The plans should indicate the requiremcnt for means of egress illumination in <br /> accordance with IBC 1C06. <br /> Please prepare a response Ictter showing whcre each item in this correction letter is addresscJ <br /> on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All requi:ed submittals shall be of sufficient detail and contain suffieient information to ensure � <br /> that the proposed structure will be constructed in compliance wilh all adopted codes. ` <br /> t <br /> Sincerely, <br /> .,�•.•..�F;, ���� ��/��,,. , <br /> � �l <br /> Sleve Miller <br /> Associate Engineer i <br /> � <br /> i <br /> � <br /> j <br /> � <br /> � <br /> l ' I � . <br /> utu��r�Av'K�,s�fl�Afu.�1x�.ms��.au�,P°oa W qn) . <br />
The URL can be used to link to this page
Your browser does not support the video tag.