My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6003 23RD DR W 2018-01-01 MF Import
>
Address Records
>
23RD DR W
>
6003
>
6003 23RD DR W 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2019 10:03:30 AM
Creation date
4/1/2017 10:13:13 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
6003
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i �/�•:./ L1VV IV . IJ Il1I1 YCJCJIVIv� I�I�VLL/VLJ <br /> Plans for such system shall be s.�bmitted to tae Fire Marshal for;�view and appro�'al prior to <br /> ins-allation. Submittal shall include cut sheets of all equipment intended for use. Appropriate trip <br /> tzsts, �aitnessed by a Fire Department inspector, shall be performed, along with a cenificate of <br /> completion, prior to final acceptanc� of the system, <br /> Fire alarm systems shall be installed according to NFPA Standazci 72. Installation ot Yre alarm <br /> components, including basic wiring, mny not commenee before plans are appraved by the <br /> Fire Department Plan Re�•iewer. Fire a!arm drswings must be professional!y rendered, in <br /> sufficient detail, and must be internally consistent. Riser diagrams must match installation plans <br /> and load cnlculations. Components must be listed and approved for use together. Changes to <br /> plans must in�lude new drawings and ca;culations and must be appruved by the Fire Department <br /> Plan Reviewer prior to installation. Fire alann installation is subject to field inspection�y a Fire <br /> Deparunent Inspector. An approved set of plans and tbe �uilding Department electrical permit <br /> must be present for any installation inspection. <br /> Fire alarm systems shall be installed under permit of the Cin� of Everett Building Department. <br /> Electrical inspections and approval are raquired prior to calling for acceptance tests, Fot permit <br /> information call (42�) 257-SSIO. <br /> The absence of working phone lines for the alarm system �vill be cause for postponing ftre <br /> department inspection and te9ting and shall re9ult in denial vf occupancy. <br /> 10. Fire Sugpression (SQrinklerl Sti�stem - An approved automatic suppression s}�stem shall be <br /> provided as required by City �rdinance\o, 1902-92, Chapter 16.76, of che E•�erett Municipal <br /> Code. The system must includc a mecha�nical water gong bell, <br /> Plens ier any such system shall be submitted to the Building Departmenc for examination and <br /> approval, Such plans shall include plans for the underground mains �hat will supply the sprinkler <br /> svs'tem. <br /> 'rhe cype of sprinkler to be installed a�ill be determined bp the Building Official. It may be an <br /> tiFP.4 13, NFPA 13R, orNFPA l3D system depending upon se��eral fAccors, Sprinkler <br /> , installation shall not begin without an approved and stamped set of plans from the Building <br /> Department, The Fire bepartment w•ill also re��iew the plans and shall field inspect the <br /> installation based only on approved plans that m�ast be on site. Changes to plans must be approved <br /> b� bo[h the Buildin¢ and Fire Departments. <br /> 4bot'egmund sprinkler piping shall be hydrostatically [ested as established in hFPA Standazd 13. <br /> linderground nipin¢ shall be hydrostatically tested and flushed as established in NFPA 5tandazd <br /> ?4 for private tire mains, (Below-eround ninine must be installed bv Washinaton State Patrol <br /> Licensed Under¢round Sarinkler line certified "U" instsllers. For further information, <br /> contact the State Fire �Iarst�al's Officr at(360) 570-3134 or contact the Everett �ire <br /> Department at (42�) 257-8123.) All such tests shall be �vitnessed by a Fire Depettment <br /> inspector. Call (42�) 257•6124 to make an appointment for inspection. <br /> Concraccors' materials and test certificates shall be submitted to the Everett Fire Depanment prior <br /> to issuance uf any Cenificates of Ocaapancy, <br /> 2��� <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.