|
� 15aRti-1 -ti
<br /> �w.. �-
<br /> .� � .... «� � . . j. � . � . . � �.
<br /> COAIPUwNCE ��:
<br /> � REUUIHEO� � . . • .
<br /> S C�l t,i: -,. .�"�,.,,�, � - . . ..
<br /> +e.�rd'� . • y �. � �
<br /> �j y � INSPECTiON ;��pORTANT:Suppiy Informetlo�end checfc approprlete circles In the shaded boxes.
<br /> ay� _ �'PRO�D Dlaregerd too!:.�that dan't descr�b' your bulldlnp or equlpmorrt.pII214I plece checks In
<br /> r x the iwo kf:columns.
<br /> H 9� ,
<br /> H ZH -, .. ,.� . �
<br /> Ky� � • r • �!, . ,e.,�r. � .
<br /> '�TJ H��-7 . . , � .., . � , . . �a
<br /> x z� O �� Exhaust ventlletion shell be provlded tor each dweiling unft es follows(VIAQ S 303): .
<br /> :_.._ ... ... _ ,_ :x
<br />, n o n >; _ . �
<br /> o H d Locatlod Mlnlmum et.25 w.p. MfrJmodol Fan labal CFM(.1W.G.) �
<br />� x �d � �5o�H G� •2S �.
<br />� � �o �: f�tchen tan 100 CFM �J J�i 130 �
<br /> z H� : Bathroom fan(N6TQ 1 50 CFM ¢P�A�•l �8�1 52 ccN L • 25 �
<br /> ��
<br />��� rHy � Bathroomtan(,ue�,�\ bOUFFA 2oA"� �op� �� �
<br /> o �H ; Balhroomfan(Rwel 50CFM gPonr-t Co8 " �� s: .
<br />� o t7�n n n �
<br /> �r -` Laundrytan 50CFM �P�a��-+ (o � �
<br /> ,r;
<br /> z �3 v�i � Q �0 CFM (1-2 bedrms) ' � i
<br /> Iy o�' 'ie W�le house(an' hx 80 CFM(3 bedrtns) K K�i"o o�r l D3 eF�-+ . 2 S ,�
<br /> (choose one) }a'
<br /> Q 100 CFM (4 bedrtns)
<br /> Whoie trM�se 12n: Locziion �'1�-n r�w�== Sone raUng�":��K��lan cbserthan� to .
<br /> _._, _. ceilinp) _ . r ; _
<br /> � �; � � VJtwle houso tan is i�sted�abled'!or Cortttnuous use t ��rv t � ' �„
<br /> '�,� ° Whol� hr�usa fan v;iring tor conirol routedlo Cent�al iosalqn{dehum+�at nn�y1 � f �
<br /> `� p p �a ',VJ hole house tan ntso snrves as a kitchen or hath spot tan Q Yfls �No • _ � 4•° `� � :
<br /> - ° ti a"spot tan fs desi8n2ted as ay+hole tr�use t2n;t he capac fty.s h a�l b e 1 h e�a t�e r-C F M r e q u i r e m e�l?�,4Q F��^
<br /> p O lYhote house tan shall nm cor�tirx��sty.KKchbn(25GFMI;8ath&la:rn3 (20CFMt QYes�.10 �, j
<br /> ��� p �� lnteAralad iorc.�d•alr fumace ventllatlon f1AQ;Cade;5:303 Z2(bjj ehall be synchronlzadw ha�r-�, ,�:
<br /> � > ";
<br /> �� vrfpleYausetantosup�ytreshair2o7hedwelling.�:. Yes,.�-No;: , . -r-�°
<br /> If yes, a 6'outside air inlet duc:�wl motorized�rrmer shall run from the 6uA�JinO e�en��io to
<br /> f.... � the fumace relum plenum a�xllinit ihe veMittion rate to beriveon.S5-.SO Air Ctsartges�3our
<br /> �o ?Aoddi;.�Gons to the ahove integrated forcetl air syslem may fequir�periortnan;,e testing lo a
<br /> � � m2nner�xeptablo!o lho Buiiding ONwial,to demonstr2ie.35-.5 air chang�s pnr hour
<br /> I e�'j
<br /> p p Q Mech2nical ventilatlon fan duds shail be 2 4�and Pro�eny s�ed MnQ,Tebla 3.3).
<br /> 3 Fresh alt shali be provided tor eacti dwelling`unit as toilows{VtA�,S.3�2 6'�} ` $; ;
<br /> ,.�� � � Each bedroom;'fested,scree ,ed,conuollabie,th�vugh-wall pon jz 4 Sq mi)to ihe axterwr il
<br /> '•O Each Recreation room:One wall poH as specttled tor.6edroors.
<br /> ,• J �Other endosed"habitoble"rooms:One wall port as specfliedlor�drooms.
<br /> L Overail Iiving �rea:One��rail p�rt es speciiied lor bedrooms.
<br /> ��
<br /> p '< OR�jCentrat torced air furnace which del�✓ers outeide makeup 21r throuqh the duct�ng syslem �
<br /> p �: Fecessetl Ilghling (Ixtures (S.SD2��; ��t�!I comply N:?one er more e;the totlowing:
<br /> � �� �C,t3;�d,KP�h 00 51016 Of���+��C8f15, C�UIkCd Of 60e�Ca b�rd'LLf1 G3f1 2nd CBI�IfIQ ,
<br /> � iC rated v,ith Iabie certilying . � ASTt 7 E253 tested aidea'�:riae r�.D CF�S
<br /> A�; UL isted falure encl�sed by a 11�gypboard t»r,or other manutaC�ured box
<br /> v;/Y12'ci�ararr�o lo can�ustable&,and 3'Gearan�to Insulation. _ ;, .. ". . �_
<br /> WSEC Framfng phase requ(rements:
<br /> Inspected by Daie
<br /> pnpc 4 ot 6
<br />
|