My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9901 25TH DR SE 2016-01-01 MF Import
>
Address Records
>
25TH DR SE
>
9901
>
9901 25TH DR SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2017 12:54:47 PM
Creation date
4/1/2017 12:54:35 PM
Metadata
Fields
Template:
Address Document
Street Name
25TH DR SE
Street Number
9901
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> i <br /> September 25, 2009 <br /> Greg Impola <br /> PO Box 13691 <br /> Mill Creek WA 98082 <br /> Subject: Project: Dreyer <br /> Job Address: 9901 25'" PI SE <br /> Plan Check No: B0909-026 <br /> Dear Mr. Impola: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reas ms listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2006 Internationa� Building Code,) (2006 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2006 Edition, and adopted by the <br /> Ciry of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to provide <br /> the Building Division with two new complete sets of drawings reflecting the corrections <br /> L��cu+r,� �� requested. <br /> p�N g„� Po,,�� 1. The Simpson PHD2 hold-down specified is no longer available. Provide new hold- <br /> De�a�l <br /> �� down. �g e,� grace P�cl De4-=-, � i <br /> � � y 2. The nailing specified dces not meet the minimum requirements per Table R602-3(1) <br /> IRC. Provide detail of alternate braced wall panel nailiig and anchor bolt placement. <br /> 5�-,a (��„�3. Provide insulation baffle per Section 502.1.4.5 WA State Energy Code (WSEC). <br /> Show on plans. <br /> 5�y,w d�}-��� 4. Anchor bolts shall be within 12Mof each end of each piece, not 12" from each end. <br /> ���af.,,� {�(.., 5. Poundation vents shall be located within 3'-0" of each corner. Provide minimum 1.33 <br /> sq. ft net clear ventilation. <br /> Su.�-^ ���'�� 6. Specify exterior wall sheathing, moisture barrier and rype of siding on section detai_. <br /> , � 7. Maintain minimum 6" earth to wood clearance. Show on section detail. <br /> � � 8. Provide 6 mil. black vapor barrier in crawl space. Show on plans. <br /> ( � 9. Provide minimum 18" clearance in crawl space. Show on plans. <br /> SG��� pe�q�f lO.Specify size and quantiry of ventilating openings in roof, include vented blocking <br /> and/or gable vents. <br /> f�,� Pla„ �y 11.Provide 110 volt smoke alarms with battery back-ap, interconnected per R313 IRC. <br /> �o��;�/heilman/i30909-026 (9901 'l5`h Pl SE) <br /> yz <br />
The URL can be used to link to this page
Your browser does not support the video tag.