Laserfiche WebLink
/ PUBLIC WORKS PERMIT COMMFNTS <br /> • ` < <br /> 4. Connect sfde sewer per City Standard#601. <br /> 5. Connect side sewer per City Standard #'s 601, 602, 604. <br /> G. Connect all rooftop downspouts to the side sewer. <br /> �7. Connect rooftop downspouts to the drainage system provided (or tliis lot. <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everett Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2'deep and 25' long. See attachment for <br /> more details. <br /> 9. The contractor must meel with the Public Works Inspector lo discuss potential drainage routing prior to <br /> beginning ihe project. <br /> 10. Install erosion conirol measures as determined by the Public Works inspector, such as silt fence, straw <br /> bales, swales, or erosion blanKets. <br /> 11 Install erosion conlrol measures per City of Everett Standards (or small parcels <br /> 12. Remove erosion control measures upon complelion of the projecl prior to final approval of the permit. <br /> / 13. All excavated material from foundation, sidewalk and driveways shall be hauled lo an approved, <br /> permitted site. No wasting of malerial is allowed on this building lol. <br /> '�l No dirl, mud, rocks or debris lo be lracked onto road�vay. <br /> ' / 15. No building materials lo be stacked on side�a�alks and side�valks to be kept clean and open for <br /> pedestrian travel. <br /> 1G. Adjusl waler meler box "' above sidewalk grade. <br /> 17. Remove and replace curb, gutler and side�a-alk as per Cily o(Everett Standard Plan#'s 3Q5A & 306 on <br /> lhis proposal's (rontage as direcled by ihe Public\Norks Inspector(i.e. all unused driveways and any <br /> broken or damaged area must be replaced). <br /> 18. Install a Type I concrete driveway per City of Everett Standard#307. � <br /> 19. Pave driveway irom the (ront property line out to lhe streel paving. <br /> 20. Contact the Water District for connecting provisions for this building's water and <br /> sewer services. <br /> 21. A catch basin as per Cily Slandard Plan t1402 with a gas trap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be installed, the pressure line must discharge into a private manhole, then <br /> gravity flow across the public right-of-way. <br /> 23. A sprinkler system is required for this building in compliance with ihe requirements of NFDA Standards <br /> 13D. <br /> FOR PUBLIC WORKS INSPECTION, CALL RANDY AT 4?5-339-7403 I CLIFF AT 425-339-7404 <br /> PWComm?nts ( /f <br /> I <br />