Laserfiche WebLink
:NG/NEER/NG / PUBL/C SERY/�ES OEPA/iTAIENT <br />Novembcr 5, 2008 <br />J.W. Gaswint <br />3120 Glacier Peak Ave <br />�vcrztt \VA 98208 <br />Subject: ProjecL• Gaswint'I'rnvnhomes <br />Job Address: 32'"' St <br />Plan Check No: CO810-006 <br />Dear Mr. Gaswint: <br />In response to your application for a construction pertnit, your plans have been examined and you are <br />advised that the issuance of a permit is being withheld for d�e reasoris IisteJ below. Thesc comments <br />address Uuilding issues only. Additional revisions or additions may be reyuired by odier departments <br />(such as Utilities, Planning or Pire). AII references refer to the (2006 International Building Code,) <br />(200G International Residential Code,) as amcnded by the State o1' Washington andlor �'Vashington State <br />Energy Code 2006 Edition, and adopted by the City of' Everett, unless stated otherwise. <br />In order for the processing of ��our applicatimi to continue, it will be necessary to pro��ide the <br />I3uilding Di��ision with hvo complete ne�r sets of dra«•ings reilecting the corrections requested. <br />1. Thc one-hour fire-resistive assembly is required to extend from the ground to the <br />underside of the roof sl�eathing. No portion of one unit can be adjacent to another unit <br />without a tire-rcsis!ive assembly. <br />2. LaUel "Separation Wall" details for its firc-resisti��e rating. <br />3. On Section "I" on Sheet 12, label alt components of the assembly. Praming members <br />shall not l.m spaced more than 24" o.c. (compression and tension members of truss). <br />4. Detail "H" on Sheel 1 l shows a 2x4 witli 1-inch air space for the furring, R-21 <br />insulation is required at below gradc �valis (6" thick). <br />5. Provide de(ail of post attachment on guard. Guard shall be designed to resist loads <br />specilicd in'CaUlc R301.5 IRC. <br />6. In d�aeiling units, where the opening of an operable window is located more than 72" <br />above the finished gradc or surface below, the lowest part of the clear opening of the <br />window shall be a minimum of 24 inchcs above the finishecl floor of the room m which <br />the window is located. Glazing bet���een the floor and 24 inches shall be fixed or have <br />openings through �vliich a 4 inch diameter sphere cannot pass, R613.2 IRC. <br />7. Specity lieader height for windo�vs and doors on all levels. <br />8. Specify handrail requirements on stair section and/or general notes, including diameter, <br />cicarances and return ends. <br />9. Provide (2) 6" x 12" screened openings located 1-hieh, 1-low near �.he water heater for <br />combustion air, show on plans. <br />""'"�j`i�'°Z`j�'"��ftEiT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-SB00 • Fax (425) 257-8856 <br />