Laserfiche WebLink
3/811x4" galv. lags <br />3/8" lags double at each end then alternated top and bottom 24" O.C. <br />° 2x6 P.T. ° <br />° ° <br />Detail B ledger attachment to existing structure <br />Crytalite post fasten to <br />existing concrete retaining <br />wall cap per manufacturers <br />specifications <br />with blue flutes and (4) <br />#140" SSMS per post <br />2x6 P.T. joist 16" O.C. <br />w/ 4x6 P.T. flat block <br />for railing connection <br />Crystalite post. <br />Fasten to blocking <br />per manufacturers <br />specifications <br />with (4) #14x4" <br />screws each post <br />Railing to deck <br />connection <br />Detail D <br />Upper railing to deck connection <br />3x12x24 concrete retaining wall cap <br />Detail E Lower railing to existing concrete <br />Simpson LCB 44 <br />12" diameter pier <br />w/ 4x4 post connector <br />to beam connector <br />12 min below - at top <br />existing grade Piers shall be a min of <br />12" below finish grade <br />and shall rest on undisturbed <br />soil <br />—12"—+ <br />New poured pier (2) places <br />Detail A <br />an EPB44T or sim <br />per manufacturers <br />cations <br />Existing pier (4) places <br />Existing piers at stair landing <br />CLIENT prawn ny <br />Cutler Resididence 5502 33rd Ave West Everett WA 98203 Lambert Gray, Inc. <br />Detail C <br />