My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
601 35TH ST 2018-01-02 MF Import
>
Address Records
>
35TH ST
>
601
>
601 35TH ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2021 12:14:07 PM
Creation date
4/1/2017 4:12:54 PM
Metadata
Fields
Template:
Address Document
Street Name
35TH ST
Street Number
601
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RESIDENTIAL ENERGY AND VENTILATION SUBMITTAL FORM <br />Applicant: 4V 7 ✓�" p - Application : <br />Job Type. ❑ New Addition Remodel <br />Date: �r/�j �0 • ?,a I Z <br />Conditioned Square Feet: _>5 ` <br />0,,�mnnrv- lbd Sinele Family / Duplex ❑ Residential Care / Assisted Living / Adult Family home <br />onno tAi(zrr r:HAPTFR R TARI_E 6-1 <br />Walls U <br />Walls (9 <br />Floors <br />Option <br />Glazing, %*Fa <br />of FloorDoor <br />Area <br />U-factor <br />0.20 <br />Vaulted <br />Ceilings <br />w/o Attics <br />R-38 <br />All <br />Other <br />Ceilings <br />R--09 or <br />R-38 Adv <br />Walls <br />Above <br />Grade <br />R-21 <br />Interior <br />Below <br />Grade <br />R-21 <br />w/ TB <br />Exterior <br />Below <br />Grade <br />R-10R-30 <br />Over <br />Unheated <br />ace <br />Slab <br />On <br />Grade <br />R-10 <br />d <br />❑ 1 <br />13% <br />2 <br />25% <br />0.20 <br />R-38 <br />R-49 or <br />R-38 Adv <br />R-21 <br />R-21 <br />w/ TB <br />R-10 <br />R-30 <br />R-10 <br />0.20 <br />R-38 <br />R-49or <br />R-38 Adv <br />R-21 <br />R-21 <br />w/ TB <br />R-10 <br />R-30 <br />R-10 <br />_ <br />Ch4/5 __ — -- --- -- _- <br />113 -- Ihenn:d Break Adv = Advanced Framing Supporting documentation wgwred <br />2009 WSEC CHAPTER 9 TABLE 9-1 <br />Dwelling units shall develop one point from the following options. Include Option 7 if applicable. See list on the back of this form. <br />❑ f lot Applicable (Additions less than 750 s.f.) <br />X,la (1.0 pis) ❑ Ic (L0 pts) ❑ 3a (0.5 pts) ❑ 3c (2.0 pis) ❑ 4b (LO pis) ❑ 5b (1.5 pis) ❑ 7 (-1.0 pis) <br />❑ Ib (2.0 pis) ❑ 2 (1.0 pis) ❑ 3b (1.0 pis) ❑ 4a (0.5 pis) ❑ 5a (0p pis) �0 6 (LO pis) ❑ 8 (0.5 Pis) <br />CONDITIONED SO. FT. �7f7�I X GLAZING % SO. FT. ALLOWED GLAZING <br />(Including Overhead w/ U > 0.35) <br />VAPOR RETARDERS: <br />CRAWLSPACE 6-mil Black Poly ❑ 3'/d' Concrete Slab ❑ N/A <br />FLOORS ❑ 4-mil Poly Face Stapled Backed Batts ❑ Ext. T&G Plywood ❑ 6-mil Poly (Slab On Gradc Floor) <br />WALLS ❑ 4-mil Poly g Face Stapled Backed Batts ❑ * Vapor Barrier Primer ❑ N/A (R-5 Exterior Rigid Ins.) <br />CEILINGS ❑ 4-mil Poly jX Face Stapled Backed Batts ❑ ' Vapor Barrier Primer ❑ N/A (>_ 12" Vent Space Over Ins.) <br />Perm Rating..<_ 1.0 ❑ N/A (All Insul. On Roof Deck) <br />VENTILATION SYSTEM: <br />Each dwelling unit shall be equipped with one of the ventilation systems listed below. Additional system information available. <br />❑ Not Applicable (Additions lass than 500 s.f.) <br />❑ Whole -House Exhaust Fan with fresh air port (net 4 sq. in. minimum opening) at each habitable room. <br />A timer operates an exhaust tan which pulls outside air through air inlets located in each habitable room. <br />�( Integrated System with fresh air duct connected to return air duct of forced -air heating system. <br />A timer operates the furnace blower and a motorized outside air inlet damper to distribute outside air through the healing ducts. <br />❑ Supply Fan with fresh air duct connected to supply air duct or return air duct of forced -air heating system, or other ducts. <br />A timer operates a supply Ian connected to an outside air dint to distribute outside air through the healing ducts or other ducts. <br />❑ Heat Recovery System. <br />A timer operates a heat recovery ventilator (HRV) to olstribute outside air to habitable rooms through dedicated ducts. <br />❑ Designed System per IM C with calculations and/or performance testing. Includes: ❑ Whole -house tan ❑ Fresh air ports <br />Typicallysuch systems must be designed, installed, tested, and balanced by a mechanical engineer or other HVAC professional. <br />Continuously operating exhaust ventilation systems shall provide the minimum now rates specified in "fable M1508.2. <br />Intermittently operating exhaust ventilation systems shall provide now rates per Table 1015082 as modified by Table M1508.3. <br />... A,. ini. tr,° c„�t°m v°ntnatinn Rate calculation on the back of this form. <br />AIR TESTING: <br />�Duct Leakage Test Required whenspace-conditioningequip/nentisinstatied, altered, orreplaced(includingreplacementotair <br />handler, outdoor unit of air conditioner or heat pump, cooling or heating coil, or furnace heat exchanger). <br />tzf Building Leakage Test Required for additions greater than or equal to750s.Land for all now construction. <br />
The URL can be used to link to this page
Your browser does not support the video tag.