My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10200 19TH AVE SE COSTCO FUEL STATION 2016-01-01 MF Import
>
Address Records
>
19TH AVE SE
>
10200
>
COSTCO FUEL STATION
>
10200 19TH AVE SE COSTCO FUEL STATION 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2017 9:21:02 AM
Creation date
4/2/2017 9:18:16 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10200
Tenant Name
COSTCO FUEL STATION
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
372
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GEOTECHNICAL ENGINEERING STUDY <br /> Costco Wholesale <br /> c/o Barghausen Consulting Engineers E-8556 <br /> January 13, 1999 Page 12 <br /> Asphalt concrete (AC1, aspnalt-treated base (ATB), and crushed rock base (CRB) materials <br /> should conform to WSDOT specifications. Rock base should be compacted to at least 95 <br /> percent of the AS7M D-1557 laboratory test stanilard. <br /> LIMITATIONS <br /> Qur recommendations and conclusions are based on the site materials observed, selective <br /> laboratory testing and engineering anaiyses, the design information provided to us by you, and <br /> our experience and engineering judgement. The conclusions and recommendations are <br /> professional opinions derived in a manner consistent with that level of care and skill ordinarily <br /> exercised by other members of the profession currently practicing under similar conditions in <br /> this area. No warranty is expressed or implied. <br /> The recommendations submitted in this report are based upon the data obtained from the <br /> exploratory borings. Soil and groundv �ter conditions between borings may vary from those <br /> encountered. The nature and extent of variations between our exploratory locations may not <br /> become evident until construct�on. If variations do appear, ECI should be requested to <br /> reevaluate the recommendations of this report and to modify or verify them in writing prior <br /> to proceedinc� with the construction. <br /> Additional Services <br /> We recommend that ECI be retained to perform a general review of the final design and <br /> specifications to verify that the earthwurk and foundation recommendations have been <br /> properly interpreted and implemented in the design and in the construction specifications. <br /> We also recommend that ECI be retained to provide geotechnical services during r.onstruction. <br /> This is to observe compliance with the design concepts, specifications or recommendations <br /> and to allow design changes in the event subsurface conditions differ from tt�ose anticipated <br /> prior to the start of construction. We do not accept responsibility for the performance of the <br /> foundation or earthwork unless we ara retained to review the construction drawings and <br /> specifications, and to provide construction observation and testing. <br /> Ear�h Cansultonts, nc '�, <br /> I� <br />
The URL can be used to link to this page
Your browser does not support the video tag.