My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10217 19TH AVE SE 2016-01-01 MF Import
>
Address Records
>
19TH AVE SE
>
10217
>
10217 19TH AVE SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2017 9:33:49 AM
Creation date
4/2/2017 9:32:49 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10217
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
241
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> : � • . . <br /> 2001 Wasliinglon S�ele Nmresitlm�ial Energy COEe Complunce Fams ReviseE Ju�w 2002 NJM <br /> Envelope - nera eqwrements <br /> 1311 Insulation ProduC sampes used(or U-fxtor delerminalior�shall be <br /> ta11.1 Irstallatfon Requiremenb: Ap insulation materials F�oduc6on 5ne units or represeMative af units as purchased by <br /> shall be installed accordng to the manufacturer's instructions �e consurneror contraclor. UNabeled glazing and doors shall <br /> be assigned thedefault U•factor n Section 2006. <br /> to achieve properdensities,maintain cleareruxs,and maintain �312.2 Solar Fleat Gain Ccefficient and Shadin <br /> unifortn R-values. To the maxinum extent possible, insJffiion 9 <br /> shall eMend over the fuu mmponent area to the intended R- CoefflcieM: Sdar HeatGain Coefficient(SHGC), shall be <br /> value. delermined, certified and labeled in accordance with the <br /> 1311.2 RooflCeilfng Insulatlon:Open-dovm or poured�oose- Nationa�Fenestration Ratlng Council(NFRC)Standard W, a <br /> fll insulation may be used in attic spaces where the slope of ��'fied, independent agenq, licensed by the NFRC. <br /> the ceiling is not more fhan 3112 ard there is at least thirty Exception: Shading ccefficients(SC)shall be an <br /> inches of cleardistance from the top of the bottan chord of the acceptable atternate for compliance with solar heat <br /> truss or ceiling joist to the underside of the sheathing at the gain coefficient requremenfs. Shading coeffiden;s <br /> roof ridge.When eave vents are installed, bafAing of the vent forglazing shall be taken from Chapler 27 o( <br /> openings shall be provided so as to deFlect the incoming air Stan,iard RS27 or from the manufactirers testdata. <br /> above the surface of the insulation. 1913 Molsture Control <br /> Where lighting 6xtures are recessed into a suspended or 1373.1 Vapor RcKarders:Vapor retarders shall be installed on <br /> exposed grid ceiling,the roof/ceiling assembly shall be ihe warm side(in winter)of insulation as required by this <br /> insulr.ted in a IocaUon other than directly on the suspended ser,lion. <br /> ceiling. Exceptloo:Vapor retarder installai with not more <br /> Exception: Type IC reted recessed lighting fixWres. than 1/3 of the nomin2l R-valuc��et��een it and the <br /> Where installed in wood 6arning,faced batt insulation conditioned space. <br /> shall be face stapled. 1313.2 RooflCeiling Assembltes:RooUceiling assemblies <br /> 1311.3 Wail Insulation:Exterior wall cavities isolated during W�re the ventilation space above the insulatbn is less than <br /> 6aming shall be fuly insulated to the levels ofthe surrounding an average of Iwelve inches shall be provided with a�oapor <br /> walls. When installed in wood Baming,faced batt insJation retarder. Roofl:eiling assemblies without a vented airspace. <br /> shall be face stapled. •Nhere neither the ronf deck nor the roof strucWre are made of <br /> Above grade exterior insulation shall be protected. W�d, shall provide a wn6nuous vapa retarder wdh taped <br /> se�ms. <br /> 1311.4 Fluor Insulatlon: Flow insulation shall be installed in Exception: Vapa retartiers neeo nut be prwided <br /> a pertnanent manner in substantial contact with the surface w}iere all of the insulation is installed between the <br /> being insulated. Insulation supports shall be installed so roof inembrane and the structural roof deck <br /> spxing is not more than twentydour inches on ceMer. <br /> �nsfalled insulation shall not block the airAow through 1313.3 Walls:Walls separe6ng conditioned space Gom <br /> �txmdatio�vents. unconditioned space shall be proNded with a vapa retarder. <br /> 1311.6 S�ab-On�rade Floor: Slab-on-grade insula6on 1313.4 Floois:Floors separating coMitioned space irom <br /> installed inside the foundation wall shall extend downward from unconditioned space shall be prrnided with a vapor retarder. <br /> the top of the slab a minimum distance of twenty-four inches or 1313.5 Crawl Spaces:A ground cover of six mil(0.006 inch <br /> to the top of the foo6ng,whichever is less. Insulation installed thick)black polyethylene or approved equal shall be laid over <br /> oulside the foundation shall eactend downNerd a minimum of the ground wilhin trawl spaces.The ground cover shall be I <br /> lwenry-four inches or to the hosVine,whichever is greater. overlapped hvelve inches minimum at thejoints and shall <br /> Above gade insulation shall be protected. extend to the foundalion wall. lil <br /> Exception: For mondilhic slabs,the insulation shall Exception:The ground crner may be anitted in <br /> extend downward frcm the top of the slab to the cravA spaces if the crawl space has a concrete slab � <br /> battom ofthe footing floor with a mir9mum thickness of three and one-half ��, <br /> 1311.6 Radiant Floors(on or belaw grade): Slab-on-grede inches. � <br /> iiuu�ation shall extend downward(rom the top of the slab a 1914 Air Leakage '.� <br /> rt:inir:+��m di;tance of thirty-six inches or do�mward to lhe lop of �314.1 Buildf ng Envelope:The requirements of�his section '�. <br /> tha foouiig and horizontal for an aggregate of not less than shall apply to buiiding elements separatiry conditioned from j <br /> thiity-siz inches. unconditioned spaces. EMeriorjoints around windows and <br /> If required by the building official wheresoil conditions door frames,openings between walls and foundatioR betv.een <br /> warcant such insulation, the entire area of a radiant floor shall walls and roof and wall panels;openirqs at peretrations of <br /> be the�malty isolated from the soil. Where a soil gas contrG utiliy services through walls,Aoors,and roofs; and all dher <br /> system is provide� belav the radiant(loor,which results in openings in the building envelope shall be sealed, caulked, <br /> increased convective fiow belrnv the radiant Aoor,the radant gasketed, or�atherstripped to limit air!=_akage. <br /> Aoa shall be thermally isolated from the sub-Floor gravel layer. 1314.2 Glazing and Doors:Doas and cperable glazina <br /> 1312 Glazfng and Doors separating condi6oned from uncon6tioned space shall be <br /> 1312.1 Standard Prceedure for Determination of Glazing weathersMpped. Fixrxl window-�shali be 6ght fMing with glass <br /> and Dour U-Factors: U-factors fa glazirg and doors shall be retained by stops with sealant or caullang all around. <br /> dMermined, certified and labeled in accordance wilh Standard Exception: OpeNngs that are requPed to be fire <br /> RS-31 by a certified iMepe�ident agency licensed by the resistant <br /> National Fenestration Rating Council(NFRC). Canpliance 1314.3 Buildfng Assemblies Used as Ducts or Plenums: <br /> shall be based on the Residential or the NonresiderRial Model Buikling assemdies used as ducts or plenums shall be sealed, <br /> Size. caulked, and gasketed to limil air leakage <br /> � <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.