My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10315 19TH AVE SE SITE DEVELOPMENT 2016-01-01 MF Import
>
Address Records
>
19TH AVE SE
>
10315
>
SITE DEVELOPMENT
>
10315 19TH AVE SE SITE DEVELOPMENT 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2017 9:50:17 AM
Creation date
4/2/2017 9:49:57 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10315
Tenant Name
SITE DEVELOPMENT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
140
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F VERGREEN ENGINEERING SERVICES INC. <br /> LAiJD �JSE PLANNING • CIViI �NGINEERING R. Alan Murray, P.E. <br /> August 13, 2004 2779p <br /> Ms. Jane Zimmerman <br /> City of Everett Public Works <br /> 3200 Cedar Street <br /> Everett, WA. 98201-4516 <br /> Re: MJR Development Silver Lake Medical <br /> Dear Ms. Zimmernan: <br /> This letter is written in response to your commer.ts regarding riser discharge "weir coefficienP' <br /> and"orifice coefficicnP'discrepancies: <br /> We corrected the two numbers in the riser input table of Watenvorks that you pointed out were <br /> reversed, re-computed the input table as is to see if the result would affect the restrictor/detention <br /> design. [t appears that the only changes were in the peak outfall of the 100 year 24-hour storm as <br /> well as the high water surface for the ]0 and 100 year storm events. These changes, however are <br /> within the acceptable parameters nfdesign. <br /> Plcase find attached the revised calculations as well as :letails of both the restricror manhole and <br /> vault cross section as an Addendum to the drainage report as they will be reflected and depicted <br /> in the subsequent and/or the final submittal. Additionally we are sending a copy of the <br /> manufacturer's printout that includes a capacity graph for the submersible effluent pump as <br />, requested. <br /> Sincerciy, <br /> Evergreen Engineering Services Inc. <br /> //-��!�.�". ` <br /> �� <br /> ! <br /> R. Alan Murray, P.E. <br /> Principal <br /> NAM/mpi:2779A/Rc�x�rt/2779M"LimnASl3W.doc `O � � � II IYI � D <br /> ll LI LS <br /> EfIC�OSUiCS <br /> AUG 1 61004 <br /> cc: Gordon Witcher � ��ITY OF EVER�j-?""' <br /> I Parmit ServiCes <br /> 30 <br /> � <br /> 8625 Evergreen Way, Suite 215 • Everetl, Washington 982D8-2620 • Phone:425•513-250D • Fax:425-355-1307 <br />
The URL can be used to link to this page
Your browser does not support the video tag.