Laserfiche WebLink
. - <br /> • • ' • ' . <br /> 1001 WUNnpp1 SbN NoneWMktl Fne%CoOs ConW Wb F>IM IYNM0.4M 2007-IfJM <br /> Lightlng -General Requirements 761�.6 Automatk Shut-0It Controls,�rior:�ro�or <br /> 761�Lightlny Controls. Lighting,induding exempt li3hting in �ipMing not intended Por 24-hour oon8nuous use ehall be <br /> SeN:�n 1512,shall comply with this section.Where occupancy automatlaly awit�hed by timer,photocell,cr a combinatlon of <br /> sensors are cited,thay shall have the features listed in Section timer and photocell.Aulomatic time switches must also bave <br /> 1513.6.1.Where automatic time switches are cked,they shall Frogrem badc-up capabilities,which provent tl�e bss of , <br /> have the features listed in Sedion 1513.6.2. Pro9rem and time settings for at least 10 hows,ff power is . <br /> inlerrupted. , <br /> 157�.1 Loeal Control and Acc�wibitily:Each space, 1613.8 Automatic 4but-0ff Controls,Int�dor:Olfice ' <br /> enGosed by walls or ceiling-height partRions,shall be provided buildings greater than 5,C00 sq.1L and all acheol Gaasrooma I <br /> with lighting controls lowted within that space.The lighting ahall be equipped with sepante automatic controls to shut oB � <br /> controls,whether one or more,shatl be capable of luming ofl the lightinfl during unoccupied hours.Autumatic controla may '�� <br /> all lights within the space.The controls shall be readily pe an occupanq senaor,time swi!ch,or clher devica capabb �� <br /> accessible,at the point of entry/exit,to personnel occupying or of automatica!ly shutting oB lightlng. <br /> using the space. <br /> El(CEPTIONS:The foliowing lighting controls may be EXCEPTIONS: <br /> 1. Areas that musl be continuc usly illuminated,or <br /> centrelized in ramote locations: illuminated in a manner requiring manual <br /> 1. Lighting controls for spaces which must be used <br /> as a whole. operation at tha lighting. <br /> 2. AutomaGc controls. 2. Emergenq lighting syalems. <br /> 3. Switching for indushial or m¢nutacturing process <br /> 3. Confrols requiring lrained operetors. facilities as may be required for produdion. <br /> 4. Controls tor safery hazards and security. <br /> 1b13.2 Area Contrels:The maximum IigMing po�ver tiiat may �613.6.1 Occupancy Sensors:Gaupancy sensors shall be <br /> be controlled from a single switch or automatic conUol shall not �Pable ot aWomatically tuming off all the lighb in an area, no <br /> exceed that which is provided by a N✓enty ampere cirait more than 30 minutes aRer the area haa been vacated. <br /> loaded to not more than eighty percent.A master control may 161�.6.2 Automadc Time Switohs:Automalic Ume switches <br /> be installed provided the individual switches retain their shall have a minimum 7 dey Godc and be capable of being set <br /> capability to fundion independently.Circuit breakers may not for 7 diHerent day ypes per week and incorporate an automatic <br /> be used as the sole means of switching. holiday"shutoH'feature,which tums oH all loads(or at least <br /> EXCEPTIONS: 24 hours and then resumes nortnally scheduled operations. <br /> 1. Industrial or manufaduring process areas,as Automatic time switches shall also have program back-up <br /> may be required for produdion. capabilities,which prevent the lou of program and tima <br /> 2. Area�less than five percent of footprint for setlings for at least 10 hours, if power is intertupted. <br /> footprints over 100,000 square feet. Automatic time switches shall incoryorete an over-ride <br /> 1513.1 Daylight 2one Control:All daylighted zones,as ��tching device which: <br /> defined in Chapter 2,both under overhead glazing and a) is readily accessible; <br /> adjacent to vertical glazing,shall be provided with individual b) is located so that a person using the device cFin see lhe <br /> controls,or daylight�or occupant-sensing automatic controis, lights or the areas controlled by the switch,or so that the <br /> which control the lights independent of genenl area lighting. area being illuminated is annunciated;and <br /> Contiguous daylight zones adjacent to vertical glazing are c) is manually operated; <br /> allowed to be controlled by a single controlling device provided d) allows the lighting to remain on for no more than two hours <br /> that they do not indude zones facing more than hvo adjacent �en an over-ride Is iniliated;and <br /> cardinal orienlations(i.e. north,east,south,west).Daylight e) controls an area not exceeding 5,000 aquare feet or 5 <br /> zones under overhead glazing more than 15 feet from the percent of footprint for footprints over 100,000 squaro feet, <br /> perimeter shall be conlrolled separately from daylight zones ��chever is greater. <br /> adjacent to vertical ylazing. 1513.7 Commissioning Rsquirem�nb:For IighGng conVols <br /> EXCEPTION: which indude daylight or occupant sensing automatic conlrols, <br /> Daylight spaces endosed by wails or ceiling automatic shut-oH controls,occupanq sensors,or automatic <br /> height partitions and containing 2 or fewer light lime switches,the lighting controls shall be tested to ansure <br /> fixtures are not required to have a separate switch for that conhol devices,components,equipment and systems are <br /> general area lighting. calibrated,adjusted and operate in accordance with approved <br /> plans and specifications.Sequences of operation shall be <br /> 1513.4 Display,Exhibition,and Speclalty Lighting fundionally tested to ensure they operate in accordance with <br /> Conhols:All display,exhibition,or specialty lighting shall be approved plans and specifications.A compbte report of test <br /> conlrolled independently of general area lighting. procedures and results shall be prepared and filed with the <br /> owner. Drawing notas shall require commissioning in <br /> accordance with this paragraph. <br /> �% <br />