Laserfiche WebLink
r°� <br /> � �; <br /> k1 <br /> Plan Check No. 92/36209 <br /> Page Three of Four <br /> �/16. Six foot, 8 inch minimum headroom clearance for stairways is <br /> , required. Section 3306(p) . Note that this is measured vertically <br /> from e plane tangent to tha stairway tread nosing. <br /> (/17. Handrails must have the�.r ends raturned or terminate in newel posts or <br /> safety terminals. Section 3306(�) . <br /> ✓18. Guardrails for stairs, balconies, and landings shall conform with <br /> Section 1712. Note that maximum clearance between intermediate rails <br /> is less than 6 inches and guardrail height should be 42 inches. <br /> (Guardrails at the sides of open stairways may have a height as <br /> • permitted for handrails) . Section 1712. <br /> �9. Enclosed usable space under stairs must be protected on the enclosed <br /> sida as required for 1-Hr fire-resistive construction, Section <br /> 3306(m) . See also Section 3309(f) . <br /> �20. Exit courts must have a minimum width of 44 inches and an unobstructed <br /> height of 7 feet except for pro�ections permitted in corridors. <br /> Section 3311(b) . <br /> �1. Exterior stairs should not project into an area (yards or courts) <br /> whera wall openings are not permitted or must be protected. Section <br /> ' 3306(n) . <br /> �12, Openings in exterior wal�s below and within 10 feet of exterior <br /> stairways shall be protected with self-closing three-fuurths-Hr <br /> fire-resistive assemblies. Section 3306(1). <br /> y/Z3. Walls and floor separating dwelling units in i:he sam� building shall <br /> be of not less than 1-Hr fire-rasistive construction. Saction 1202(b). <br /> �4. A Group R, Division 1 Occupancy more than two stories in haight or <br /> having mora than 3,000 squara feet above the first story shall be of <br /> 1-Hr fire-resistive construction throughout Section 1202(b). <br /> �5. Provide smoke detectors per Section 1210. <br /> �6. Complete plans per the attached "highlighted" checklist. <br /> I <br />