Laserfiche WebLink
. � <br /> 4. Provide roof framing plan. Show all ridges, hips and �•aYleys. Show ail special <br /> trusses; hipmaster, girder c:tc.. Show posts or mulriple studs imder point lc+ads <br /> from trusses. Tnce all loads to the foundadon. <br /> 5. 2 x 4 studs are called out between the garage a��d ►�ving spa�;e on b�.�th units, R-19 <br /> insulation is required on exterior walls and in walls se.paza6ng h�aled and <br /> unheated spaces. <br /> 6. Footings at columns are required to be 1Q" thick with 24" x 24" conr,rete footings. <br /> u <br /> 7. Wall bracin el f" cannot be use.�S on the second story. It is only allowed on <br /> 8 P� <br /> the first floor of a two-story. Provide a different wall bracing pa��el on the <br /> second floar. <br /> 8. A floor or landing is required at each entrance or exit. Provide min. 36" landing <br /> not more than 8" below the finished flewr. <br /> 9. Provide stair details and/or secGons. Show stair requirements, handrail, guazdrail <br /> and ceiling height requirements. <br /> 10. All walls, posts and beams sapporting a living space ahove a garage are required <br /> W have one-hour fua resistive construction on the garage side. Specify protecfion <br /> requirements on plans. <br /> 11. Provide all dimensions on foundadon plan. Show hold-downs. <br /> 12. Label all wall bncing panels on plans (second floor of unit A�5 Cg? stairs/bedroom <br /> lil). <br /> 13. The foundation plan shows the width of unit;�5 as 31'-6'h". The floor plan <br /> shows 31'-6". Please clarify. <br /> 14. Spxify skylight size(s) on pla��. <br /> 15. Specify roof framing of dormer at both Gnits. Show header size(s) and specify <br /> i,isuladon. Provide detail of cantilever. Show floor framing including double <br /> joisu on foundation plan. <br />