Laserfiche WebLink
Proposed Area Calculations <br />Approximately 44% and 56% of the Proposed PDA is impervious and pervious <br />respectively. <br />The project will cause a net new impervious increase of 16,700 square feet (0.38 <br />Acres/ 3%). About 113 of this 16,700 square feet is Non Pollution Generating <br />Impervious Surface (NPGIS) and 2/3 is Pollution Generating Impervious Surface <br />(PGIS). <br />v Approximately 21% of the Proposed PDA is Pollution Generating Impervious <br />Surface (PGIS). This represents a net increase of 2% (9,800 so. <br />Approximately 32%of the Proposed PDA is Pollution Generating Pervious Surface <br />(PGPS). This represents a net decrease of 3% (16,700 so. <br />See Proposed Area Calculations in Appendix A. <br />Redevelopment—24.30.025 SCC <br />The Silver Lake Elementary Parking Lot Expansion Project meets threshold requirements <br />for Redevelopment as specified in SC24.30.025, and as communicated by PDS Staff <br />(Randy Sleight/Ken Crossman) on December 5, 2002. <br />Water Quanti. j+ Treatment - Detention facilities have been provided to <br />adequately meet requirements of 24.30.025(1). Flow control is being provided <br />for mitigation of increased peak flows from New and Replaced surfaces. The <br />Director has not imposed additional flow control requirements for this project. <br />For water quantity control calculations, predeveloped site conditions have <br />assumed forested cover and a volume correction factor of 1.3 has been applied. <br />IVater Quality Treatarent -The project cannot feasibly provide water quality <br />treatment for the entire site per 24.30.025(2) b. A Drainage Variance Request <br />has been submitted tinder separate cover. <br />In summary, water quality treatment has been provided to the maximum extent <br />feasible for all of the new and replaced areas plus two other existing parking lots <br />— the West Parking Lot and the South Parking Lot - respectively. in addition, <br />many previously untreated pollution generating areas are being relocated or <br />demolished as a result of the new construction including the child care building, <br />the northwest parking lot and the north parking lot. <br />Approximately 89% (237,000 so of the PGIS and PGPS will be treated with <br />facilities provided during playfield upgrades in 1998 and with facilities provided <br />with this parking lot expansion. Approximately 11 % (30,000 so of the <br />pollution generating areas will remain untreated. They include the west building <br />with built up asphalt roof (17,300 so, the south access road (8,600 so, and some <br />of the proposed northwest parking lot landscape areas (estimated 4,000 so. As <br />described in the Variance Request, these areas can neither be economically treated <br />nor physically connected in a reasonably feasible manner. <br />Targeted Drainage Report for Everett Public schuals Section 2 — Risk & Erosion Control <br />silver lake Elementary Parking Lot Expansion January 6, 2003 <br />_ I By: Pertecl Engineenng Page 5 of 7 <br />