STRUCTURAL STEEL NOTES ELECTRICAL NOL�: <br />GENERAL NOTES: <br />1. ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE <br />WITH THE PROJECT SPECIFICATIONS AND IN ACCORDANCE <br />WITH ASTM A36 UNLESS OTHERWISE NOTED. <br />2. ALL WELDING SHALL BE PERFORMED USING E70XX <br />ELECTRODES AND WELDING SHALL CONFORM TO AISC AND <br />AWS D1.1. WHERE FILLET WELD SIZES ARE NOT SHOWN, <br />PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC <br />'MANUAL OF STEEL CONSTRUCTION'. PAINTED SURFACES <br />SHALL BE TOUCHED UP. <br />3. BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING <br />TYPE (3/4"0) CONNECTIONS AND SMALL HAVE MINIMUM <br />OF TWO BOLTS UNLESS NOTED OTHERWISE. <br />4. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY <br />USE 5/8' DIA. ASTM A 307 BOLTS UNLESS NOTED <br />OTHERWISE. <br />INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, <br />SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED <br />PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL <br />CONFORM TO MANUFACTURER'S RECOMMENDATION FOR <br />EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO <br />REBAR SHALL BE CUT WITHOUT PRIOR ENGINEERING <br />APPROVAL WHEN DRILLING HOLES IN CONCRETE. SPECIAL <br />INSPECTONS, REQUIRED BY GOVERNING CODES, SHALL BE <br />PERFORMED IN ORDER TO MAINTAIN MANUFACTURER'S <br />MAXIMUM ALLOWABLE LOADS, <br />6. INSTALLATIONS WHERE THE GENSET IS LOCATED NEAR <br />EXISTING CABLE TRAY SHALL HAVE A NOTE ON THE <br />DRAWINGS CALLING FOR GRIP STRUT INSTALLATION OVER <br />THE TRAY FOR TO PROVIDE FOR A WALKWAY FOR TECHS <br />AND SERVICE PERSONNEL <br />7, EXISTING PLATFORM INSTALLATIONS SHALL INCLUDE THE <br />INSTALLATION OF AN ANGLE UNDER THE STRUCTURAL <br />MEMBER OF THE PLATFORM TO SECURE THE GENSET TO <br />THE PLATFORM IN LIEU OF THE GATING. <br />B. SURFACE MOUNTING OF CONDUITS SHALL BE AVOIDED AT <br />ALL POSSIBLE LOCATIONS WHERE PEDESTRIAN TRAFFIC <br />CAN OCCUR. WHERE THIS IS UNAVOIDABLE, GRIP STRUT <br />BRIDGING SHALL BE CALLED OUT FOR INSTALLATION TO <br />PROTECT THE CONDUITS AND POTENTIAL FOR PERSONNEL <br />TRIPPING HAZARDS. <br />1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL <br />INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE <br />SPECIFIC CONDITIONS. <br />2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND <br />OTHER METALLIC COMPONENTS USING GROUND WIRES AND <br />CONNECT TO SURFACE MOUNTED BUS BARS. FOLLOW <br />ANTENNA AND BTS MANUFACTURERS PRACTICES FOR <br />GROUNDING REQUIREMENTS. GROUND COAX SHIELD AT <br />BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S <br />PRACTICES. <br />3. ALL GROUND CONNECTIONS SHALL BE CADWELD. ALL WIRES <br />SHALL BE COPPER THHN/THWN. ALL GROUND WIRE SHALL <br />BE GREEN INSULATED WIRE ABOVE GROUND. <br />4. REFER TO DMSION 16 GENERAL ELECTRIC; GENERAL <br />ELECTRICAL PROVISION AND COMPLY WITH ALL <br />REQUIREMENTS OF GROUNDING STANDARDS. <br />S. RIGID CONDUIT SHALL BE USED WHERE DAMAGE CAN <br />OCCUR FROM VEHICULAR TRAFFIC OR EQUIPMENT DELIVERY <br />EXERCISES. <br />6. ATS AND GENSET LABELS ARE TO BE PROVIDED AND <br />INSTALLED WITH SERIAL AND CASCADE NUMBERS FOR THE <br />ATS AND GENSETS. LABELS SHALL BE ATTACHED VIA <br />JLUMINUM OR SS SCREWS - CONSTRUCTION MANAGER TO <br />PROVIDE TO SUBS FOR INSTALL AT SITE, DUE TO POSSIBLE <br />ASSET TRANSFER ACTIVITY, UPON RECEIPT OF LABEL <br />SPECIFICATION FROM SPRINT/NEXTEL <br />7, NEW INSTALLATION SHALL BE PVC CONDUIT, USE SCH 80 <br />ABOVE GROUND AND SCH 40 BELOW GROUND. ALSO REFER <br />TO CONSTRUCTION MANAGER DIRECTION FOR ANY CONDUIT <br />EXPOSED TO TRAFFIC (VEHICLE OR FOOT). <br />8. CONTRACTOR TO PROVIDE A NEW fib BLOCK IF REQUIRED, <br />WITH FURTHER ROUTING TO THE RBS EQUIPMENT CABINET <br />AND LEFT WITH A 2' COIL OF WIRE:. ALARM CABLING IN <br />THE TELCO CABINET SHALL BE INSTALLED IN A NEAT <br />FASHION WITH A 6' SERVICE COIL. CONTRACTOR SHALL <br />NOT MAKE PUNCH DOWNS ON THE TELCO BOARD 66 <br />BLOCK <br />THE SPRINT/NEXTEL METHOD OF PROCEDURE (MOP) MOPS <br />2061108 INSTALLATION OF PAD MOUNTED GENERATOR SETS <br />15 THE BASIS FOR ALL TECHNICAL INSTALLATION <br />SPECIFICATIONS; AND IN THE EVENT THERE IS A CONFLICT <br />BETWEEN THESE CONSTRUCTION DOCUMENTS OR THE <br />INSTALLATION CHECKLIST AND THE GENSET MOP, THE <br />CONTRACTOR SHALL FOLLOW THE DIRECTIVE DESCRIBED <br />WITHIN THE MOP AND CONTACT CONSTRUCTION MANAGER TO <br />APPRISE. EYCEPT NO PORTABLE GENERATOR S/0 CORD <br />STILL BE REMOVED <br />2. DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS <br />TAKE PRECEDENCE, THIS SET OF DOCUMENTS IS INTENDED <br />TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY, UNLESS <br />NOTED OTHERWISE. THE GENERAL CONTRACTOR'S SCOPE OF <br />WORK SHALL INCLUDE FURNISHING ALL MATERIALS. <br />EQUIPMENT, LABOR, AND ANY REOL':.^.EMENTS DEEMED <br />NECESSARY TO COMPLETE INSTALLATION AS DESCRIBED IN <br />THE DRAWINGS AND OWNER'S PROJECT MANUAL. <br />3. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES <br />NOT REQUIRE POTABLE WATER OR SEWER SERVICE. <br />4. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR <br />HUMAN HABITAT. (NO HANDICAP ACCESS IS REQUIRED). <br />5. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED <br />FROM SITE VISITS AND DRAWINGS PROVIDED BY THE SITE <br />OWNER. DRAWINGS WERE PREPARED FROM SITE SPECIFIC <br />DETAILS AND STANDARDIZED DETAILS DEVELOPED BY PACIFIC <br />TELECOM SERVICES, LLC. STANDARDIZED DETAILS ARE TO BE <br />CONFIRMED AND CORRELATED AT THE SITE BY THE <br />CONTRACTOR. THE CONTRACTOR SHALL FIELD VERIFY ALL <br />DIMENSIONS. MODIFICATIONS DUE TO FIELD CONDITIONS <br />MUST BE SUBMITTED TO, AND APPROVED BY, <br />SPRINT/NEXTEL PRIOR TO ORDERING MATERIAL OR <br />PROCEEDING WITH CONSTRUCTION. <br />6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY <br />DAMAGE CAUSED BY THE CONSTRUCTION OPERATION. <br />7. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL <br />PERMITS AND INSPECTIONS REQUIRED FOR CONSTRUCTION. <br />8. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM <br />THE SITE ON A DAILY BASIS. ALL INSTALLATIONS SHALL BE <br />100% CLEAN OF ALL DEPRIS AND METAL FILINGS SHALL BE <br />REMOVED FROM ENCLOSURES, SITE AREA, FIXTURES, <br />PLATFORMS, ETC. <br />9. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS <br />INVOLVED SHALL VISIT THE JOB SITE TO FAMILIARIZE <br />THEMSELVES WITH ALL CONDITIONS AFFECTING THE <br />PROPOSED PROJECT. CONTRACTORS SHALL VISIT THE <br />CONSTRUCTION SITE WITH THE CONSTRUCTION/CONTRACT <br />DOCUMENTS 10 VERIFY FIELD CONDITIONS AND CONFIRM <br />THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. <br />PRIOR TO PROCEEDING WITH CONSTRUCTION, ANY ERRORS, <br />OMISSIONS, OR DISCREPANCIES SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT/ENGINEER VERBALLY AND IN <br />WRITING. <br />10. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN <br />AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO <br />STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY <br />THE CONSTRUCTION DRAWINGS/CONTRACT DOCUMENTS. <br />11, THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE <br />PROJECT DESCRIBED IN THE CONTRACT DOCUMENTS. THE <br />CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL <br />CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, <br />AND PROCEDURES FOR COORDINATING ALL PORTIONS OF <br />THE WORK UNDER THE CONTRACT. <br />12. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND <br />MATERIALS ACCORDING TO MANUFACTURER'S/VENDCR'S <br />SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE <br />LOCAL CODES OR ORDINANCES TAKE PRECEDENCE. <br />13, ALL WORK PERFORMED ON THE PROJECT AND MATERIALS <br />INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL <br />APPLICABLE CODES, REGULATIONS, AND ORDINANCES. <br />CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH <br />ALL LAWS, ORDINANCES, RULES, REGULATIONS AND <br />LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL <br />AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND <br />STATE JURISDICTIONAL CODES BEARING ON THE <br />PERFORMANCE OF THE WORK. <br />14. THE STRUCTURAL COMPONENTS OF ADJACENT <br />CONSTRUCTION OR FACILITIES ARE NOT TO BE ALTERED <br />BY THIS CONSTRUCTION PROJECT UNLESS NOTED <br />OTHERWISE. <br />15. SEAL ALL PENETRATIONS THROUGH FIRE -RATED ARLAS <br />WITH U.L. LISTED OR FIRE MARSHALL APPROVED <br />MATERIALS IF APPLICABLE TO THIS FACILITY AND OR <br />PROJECT SITE. <br />16. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER <br />WITH A RATING OF NOT LESS THAN 2-A OR 2-A1OBC <br />WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF <br />PROJECT AREA DURING CONSTRUCTION. <br />17. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO <br />PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, <br />CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION <br />OF WORK, CONTRACTOR SHALL REPAIR ANY DAMAGE THAT <br />MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR <br />ABOUT THE PROPERTY. <br />18. THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT <br />TO SET FORTH IN THE CONSTRUCTION AND CONTRACT <br />DOCUMENTS THE COMPLETE SCOPE OF WORK. <br />CONTRACTORS BIDDING THE JOB ARE NEVERTHELESS <br />CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE <br />DRAWINGS AND OR SPECIFICATIONS SHALL NOT EXCUSE <br />SAID CONTRACTOR FROM COMPLETING THE PROJECT AND <br />IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF <br />THESE DOCUMENTS. THE BIDDER SHALL BEAR THE <br />RESPONSIBILITY OF NOTIFYING (IN WRITING) THE <br />ARCHITECT/ENGINEER OF ANY CONFLICTS, ERRORS, OR <br />OMISSIONS PRIOR TO SUBMISSION OF CONTRACTOR'S <br />PROPOSAL. IN THE EVENT OF DISCREPANCIES THE <br />CONTRACTOR SHALL PRICE THE MCRE COSTLY OR <br />EXTENSIVE WORK, UNLESS DIRECTED OTHERWISE. <br />19. THE CONTRACTOR SHALL PERFORM WORK DURING <br />OWNER'S PREFERRED HOURS TO AVOID DISTURBING <br />NORMAL BUSINESS. <br />20. CONTRACTOR SHALL CALL WASHINGTON UTILITY <br />COORDINATING COUNCIL SERVICE FOR UNDERGROUND <br />UTILITY MARKOUT PRIOR TO CONSTRUCTION <br />1-800-424-5555. <br />21. IN CASE O' CONFLICT BETWEEN THE AFORE REFERENCED <br />SPRINT/NEXTEL STANDARDS AND INSPECTION CHECK LIST, <br />THE GENERAL CONTRACTOR SHALL CONTACT <br />CONSTRUCTION MANAGERS' PROJECT MANAGER TO <br />RESOLVE, IN WRITING, ANY DEVIATIONS. <br />Together with NEXTEL <br />PACIFIC TELECOM SERVICES, <br />LLC <br />4072 <br />THOMAS R. F"ND <br />SATE OF W'ASHW=TOM 1 <br />l � <br />Q <br />G-171 <br />GENERAL NOTES <br />JOB / <br />DRAWING <br />-4" <br />G-t <br />REVISION1 0 <br />