FENCE BOND SEE DETAIL <br />SAME SHEET <br />PROPOSED 40KW <br />DIESEL GENERATOR <br />ON CONCRETE PAD — <br />GENERATOR FRAME BONO <br />SEE DETAIL SAME SHEET <br />X— x — xz_ r x — x — T' — X — x — x — x — x — x — x — x <br />4 • ------------- <br />x <br />x <br />PROPOSED /2 AWG <br />ATS CASE BOND — <br />PROPOSED <br />APPROX. LOCATION OF <br />EXISTING NEXTEL GROUND <br />RING (CONTRACTOR TO FIELD <br />VERIFY EXACT xLOCATION) <br />x— %— X APPROX. LOCATION OF <br />EXISTING NEXTEL HALO <br />(CONTRACTOR TO FIELD <br />VERIFY EXACT LOCATION)—, <br />1, EXOTHERMIC WELD ALL CONNECTIONS TO BURIED GROUND RING WITH <br />PARRALLEL TAP WELDS, USE SHORT RODS WHERE STANDARD GROUND RODS ARE <br />NOT USED, SEE CABLE TO CABLE DETAIL <br />2. M4KE ALL GROUNDING CONNECTIONS AS SHORT AS POSSIBLE, MINIMUM <br />BENDING RADIUS IS B'. <br />3. CLEAN ALL SURFACES AND BRUSH WITH BRONZE BRUSH PRIOR TO MAKING <br />GROUND CONNECTIONS. PAINT ALL EXOTHERMIC WELDS TO GALVANIZED OBJECTS <br />WITH GALVANIZE PAINT, USE E.0-OX COMPOUND WITH METAL TO METAL <br />CONNECTIONS. <br />4. INSTALL 5/8' X 10' COPPER CLAD GROUND RODS IN LOCATIONS SHOWN, <br />DISTANCE 10'-0' MINIMUM TO 15'-0' MAXIMUM BETWEEN RODS. <br />5. GROUND SYSTEM MUST BE INSPECTED BY CONSTRUCTION MANAGER PRIOR TO <br />BACKFILL, PROVIDE 24 HOURS NOTICE. <br />6. ALL BONDS SHALL BE 02 AWG BARE, THINNED, SOLID COPPER UNLESS <br />OTHERWISE NOTED. <br />7. THE GENSET SHALL BE GROUNDED TWICE IN DIAGONAL CORNERS. ONE <br />GROUND TO THE TANK FRAME AND THE SECOND TO THE GENERATOR ENCLOSURE <br />FRAME. IT IS ACCEPTABLE TO GROUND THE TANK AT BOTH LOCATIONS WITH A <br />X <br />X— X— X— x— x— x— JUMPER FROM THE TANK TO THE GENSET ENCLOSURE. THaE GROUNDS SHALL <br />BE ON THE OUTSIDE OF THE UNIT TO BE VISIBLE BY ALL <br />rt <br />❑ <br />x 2 J I <br />APPROX. LOCATION OF <br />EXISTING SPRINT GROUND <br />x RING (CONTRACTOR TO FIELD <br />�I VERIFY EXACT LOCATION)— <br />L—x—x—x—x—X—%—X—x—x—x—x—x—x—x—X—X—X—x <br />`x — x —x — x — x —% — x —x — <br />GENERATOR FRAME <br />TWO HOLE BOLTED <br />GROUND LUG. SS HOW <br />O 02 AWG TINNED WIRE <br />O <br />PREP" <br />SURFACE BEFORE GROUNDING USE NO-OX BETWEEN LUG AND STEEL. <br />USE SAME COLOR TOUCH UP PAINT TO <br />PREVENT RUST. <br />GENERATOR FRAME BOND <br />NOT TO SCALE <br />SCALE SCALE 11X1» ;:-O' i:' <br />NOTES: <br />1.POWER INTERRUPTION IS ALLOWED ONLY UNDER <br />THE FOLLOWING CONDITIONS; OUTSIDE OF THE <br />MORNING AND AFTERNOON DRIVE TIMES, CUT <br />DURATION MUST BE GUARANTEED TO BE LESS <br />THAN 2 HOURS MAX. IF THIS CAN NOT BE <br />GUARANTEED STAND—BY POWER MUST BE <br />CONNECTED OR INTERRUPTION MUST BE <br />PERFORMED DURING THE MAINTENANCE WINDOW. <br />2.EXISTING DUPLEX OR ON THE GENERATORS SWILL <br />BE CHANGED OUT TO A NON—GFl OUTLET TO <br />AVOID LOSS OF POWER TO THE BATTER' CHARGER <br />AND BLOCK HEATERS. NON—GFl OUTLET SHALL BE <br />SERVICED BY ONE 20AMP CIRCUIT IN FLEX <br />CONDUIT. <br />I <br />EXOTHERMIC WELD <br />COLD GALVANIZED FENCE POST <br />— JR AFTER COOLING. <br />V10112J <br />12' <br />FENCE BONDING I°: �'.;�!�'#----CONCRETE FOOTING <br />CONDUCTOR <br />FENCE BONDING DETAIL <br />NOT TO SCALE <br />GROUNDING PLAN <br />2 <br />GROUNDING PLAN NOTES: <br />I PROVIDE AND INSTALL #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM <br />THE GENERATOR FRAME TO THE GENERATOR GROUND ROD. <br />PROVIDE AND INSTALL A 5/8' X 10'-0' COPPER CLAD STEEL GROUND ROD <br />APPROXIMATLEY 24' FROM GENERATOR PAD, FOR CASE BOND. <br />PROVIDE AND INSTALL A R2 AWG BARE, TINNED SOLID COPPER CONDUCTOR <br />FROM THE GROUND ROD TO THE NEAREST POINT ON THE EXISTING GROUND <br />RING. <br />PROVIDE AND INSTALL #2 AWG BARE. TINNED SOLID COPPER CONDUCTOR FROM <br />THE FUEL TANK FRAME TO THE FUEL TANK GROUND ROD. <br />ATS NOTES: <br />IF THE ATS IS INSIDE THE CELL SITE ENCLOSURE, THE ATS CASE SHALL BE <br />BONDED TO THE HALO GROUND RING INSIDE THE ENCLOSURE WITH A #6 AWG <br />COPPER WIRE. IF THE ATS IS OUTSIDE THE ENCLOSURE, IT SHALL BE BONDED TO <br />THE EXTERNAL DROUND RING WITH A #2 AWG SOLID TINNED COPPER WIRE. <br />THE SURGE ARRESTORS DESCRIBED IN THIS MOP ARE TO BE MOUNTED ON THE <br />MOUNTING PLATE SOLD BY THE MANUFACTURER. THEY MAY BE GROUNDED IN ONE <br />OF THREE WAYS: <br />1. IF THE ARRESTOR MOUNTING PLATE IS MOUNTED ON THE TELCO BOARD AND <br />IF THE TELCO GROUND BAR IS BONDED TO THE EXTERNAL GROUND RING, THE <br />PLATE MAY BE BONDED TO THE TELCO GROUND BAR WITH A #2 AWG INSULATED <br />STRANDED COPPER WIRE AND SUITABLE COMPRESSIONOTYPE 2-HOLE LUGS. <br />2. IF THE ARRESTOR PLATE IS NOT MOUNTED ON THE TELCO BOARD. BOND IT <br />DIRECTLY TO THE EXTERNAL GROUND RING WITH A Q2 AWG SOLID TINNED <br />COPPER WIRE. USE A PVC CONDUIT THROUGH THE SHELTER WALL AT A 45 <br />DEGREE ANGLE TO ALLOW THE GROUND LEAD TO EXIT THE SHELTER FOR <br />BONDING TO THE EXTERNAL GROUND RING. <br />3. IF AN EXISTING #2 AWG GROUND CONDUCTOR EXISTS THE SHELTER (TO THE <br />EXTERNAL GROUND RING) WITHIN 2FT OF THE MOUNTING PLATE LOCATION, THE <br />PLATE MAY BE BONDED USING A 02 AWG INSULATED STRANDED CONDUCTOR WITH <br />A COMPRESSION TYPE 'C' TAP AND A SUITABLE COMPRESSION TYPE 2 HOLE LUG. <br />MAKE ALL CONNECTIONS TO THE ATS CASE, THE GENERATOR FRAME, THE <br />EXTERNAL FUEL TANK (IF PRESENT AND IF SUPPORTED BY THE MANUFACTURER) <br />AND THE SURGE ARRESTOR MOUNTING PLATE WITH SUABLE 2—HOLE <br />COPRESSION—TYPE LUG AAND STAINLESS —STEEL SCREWS, STAR —TYPE LOCK <br />WASHERS AND NUTS. REMOVE PAINT AT THE POINT WHERE THE COMPRESSION <br />LUG CON'AC'S THE MATING METAL SURFACE IN QUESTION TO ENSURE A GOOD <br />METAL—T-)—METAL CONTACT. APPLY ANTIOXIDANT TO THE MATING SURFACES. <br />ENSURE THAT ALL UNDERGROUND OR OUTDOOR CONNECTIONS TO A GROUNDING <br />SYSTEM ARE EXOTHERMICALLY WELDED (CAD —WELDED). <br />PERFORM AL'. GROUNDING WORK IN ACCORDANCE WITH STDS 2976175. <br />CONSTRUCTKM STANDARDS <br />ELECTRICAL NOTES <br />Together with NEXTEL <br />PACIFIC TELECOM SERVICES, <br />LLC <br />4072 <br />THOMAS R. HOLLAND <br />STATE OF WASHIN=TON , <br />1 � � <br />Q= <br />vj00x <br />w <br />E-1 <br />GROUNDING PLAN AND <br />ELECTRICAL NOTES <br />JOB / <br />DRAWING / <br />WAD41 <br />C-I <br />REVISION 1 0 <br />