9610 19TH AVE SE NEXTEL ANTENNA 2018-01-02 MF Import
>
Address Records
>
19TH AVE SE
>
9610
>
NEXTEL ANTENNA
>
9610 19TH AVE SE NEXTEL ANTENNA 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2021 10:34:14 AM
Creation date
4/2/2017 2:57:08 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9610
Tenant Name
NEXTEL ANTENNA
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FENCE BOND SEE DETAIL <br />SAME SHEET <br />PROPOSED 40KW <br />DIESEL GENERATOR <br />ON CONCRETE PAD — <br />GENERATOR FRAME BONO <br />SEE DETAIL SAME SHEET <br />X— x — xz_ r x — x — T' — X — x — x — x — x — x — x — x <br />4 • ------------- <br />x <br />x <br />PROPOSED /2 AWG <br />ATS CASE BOND — <br />PROPOSED <br />APPROX. LOCATION OF <br />EXISTING NEXTEL GROUND <br />RING (CONTRACTOR TO FIELD <br />VERIFY EXACT xLOCATION) <br />x— %— X APPROX. LOCATION OF <br />EXISTING NEXTEL HALO <br />(CONTRACTOR TO FIELD <br />VERIFY EXACT LOCATION)—, <br />1, EXOTHERMIC WELD ALL CONNECTIONS TO BURIED GROUND RING WITH <br />PARRALLEL TAP WELDS, USE SHORT RODS WHERE STANDARD GROUND RODS ARE <br />NOT USED, SEE CABLE TO CABLE DETAIL <br />2. M4KE ALL GROUNDING CONNECTIONS AS SHORT AS POSSIBLE, MINIMUM <br />BENDING RADIUS IS B'. <br />3. CLEAN ALL SURFACES AND BRUSH WITH BRONZE BRUSH PRIOR TO MAKING <br />GROUND CONNECTIONS. PAINT ALL EXOTHERMIC WELDS TO GALVANIZED OBJECTS <br />WITH GALVANIZE PAINT, USE E.0-OX COMPOUND WITH METAL TO METAL <br />CONNECTIONS. <br />4. INSTALL 5/8' X 10' COPPER CLAD GROUND RODS IN LOCATIONS SHOWN, <br />DISTANCE 10'-0' MINIMUM TO 15'-0' MAXIMUM BETWEEN RODS. <br />5. GROUND SYSTEM MUST BE INSPECTED BY CONSTRUCTION MANAGER PRIOR TO <br />BACKFILL, PROVIDE 24 HOURS NOTICE. <br />6. ALL BONDS SHALL BE 02 AWG BARE, THINNED, SOLID COPPER UNLESS <br />OTHERWISE NOTED. <br />7. THE GENSET SHALL BE GROUNDED TWICE IN DIAGONAL CORNERS. ONE <br />GROUND TO THE TANK FRAME AND THE SECOND TO THE GENERATOR ENCLOSURE <br />FRAME. IT IS ACCEPTABLE TO GROUND THE TANK AT BOTH LOCATIONS WITH A <br />X <br />X— X— X— x— x— x— JUMPER FROM THE TANK TO THE GENSET ENCLOSURE. THaE GROUNDS SHALL <br />BE ON THE OUTSIDE OF THE UNIT TO BE VISIBLE BY ALL <br />rt <br />❑ <br />x 2 J I <br />APPROX. LOCATION OF <br />EXISTING SPRINT GROUND <br />x RING (CONTRACTOR TO FIELD <br />�I VERIFY EXACT LOCATION)— <br />L—x—x—x—x—X—%—X—x—x—x—x—x—x—x—X—X—X—x <br />`x — x —x — x — x —% — x —x — <br />GENERATOR FRAME <br />TWO HOLE BOLTED <br />GROUND LUG. SS HOW <br />O 02 AWG TINNED WIRE <br />O <br />PREP" <br />SURFACE BEFORE GROUNDING USE NO-OX BETWEEN LUG AND STEEL. <br />USE SAME COLOR TOUCH UP PAINT TO <br />PREVENT RUST. <br />GENERATOR FRAME BOND <br />NOT TO SCALE <br />SCALE SCALE 11X1» ;:-O' i:' <br />NOTES: <br />1.POWER INTERRUPTION IS ALLOWED ONLY UNDER <br />THE FOLLOWING CONDITIONS; OUTSIDE OF THE <br />MORNING AND AFTERNOON DRIVE TIMES, CUT <br />DURATION MUST BE GUARANTEED TO BE LESS <br />THAN 2 HOURS MAX. IF THIS CAN NOT BE <br />GUARANTEED STAND—BY POWER MUST BE <br />CONNECTED OR INTERRUPTION MUST BE <br />PERFORMED DURING THE MAINTENANCE WINDOW. <br />2.EXISTING DUPLEX OR ON THE GENERATORS SWILL <br />BE CHANGED OUT TO A NON—GFl OUTLET TO <br />AVOID LOSS OF POWER TO THE BATTER' CHARGER <br />AND BLOCK HEATERS. NON—GFl OUTLET SHALL BE <br />SERVICED BY ONE 20AMP CIRCUIT IN FLEX <br />CONDUIT. <br />I <br />EXOTHERMIC WELD <br />COLD GALVANIZED FENCE POST <br />— JR AFTER COOLING. <br />V10112J <br />12' <br />FENCE BONDING I°: �'.;�!�'#----CONCRETE FOOTING <br />CONDUCTOR <br />FENCE BONDING DETAIL <br />NOT TO SCALE <br />GROUNDING PLAN <br />2 <br />GROUNDING PLAN NOTES: <br />I PROVIDE AND INSTALL #2 AWG BARE, TINNED SOLID COPPER CONDUCTOR FROM <br />THE GENERATOR FRAME TO THE GENERATOR GROUND ROD. <br />PROVIDE AND INSTALL A 5/8' X 10'-0' COPPER CLAD STEEL GROUND ROD <br />APPROXIMATLEY 24' FROM GENERATOR PAD, FOR CASE BOND. <br />PROVIDE AND INSTALL A R2 AWG BARE, TINNED SOLID COPPER CONDUCTOR <br />FROM THE GROUND ROD TO THE NEAREST POINT ON THE EXISTING GROUND <br />RING. <br />PROVIDE AND INSTALL #2 AWG BARE. TINNED SOLID COPPER CONDUCTOR FROM <br />THE FUEL TANK FRAME TO THE FUEL TANK GROUND ROD. <br />ATS NOTES: <br />IF THE ATS IS INSIDE THE CELL SITE ENCLOSURE, THE ATS CASE SHALL BE <br />BONDED TO THE HALO GROUND RING INSIDE THE ENCLOSURE WITH A #6 AWG <br />COPPER WIRE. IF THE ATS IS OUTSIDE THE ENCLOSURE, IT SHALL BE BONDED TO <br />THE EXTERNAL DROUND RING WITH A #2 AWG SOLID TINNED COPPER WIRE. <br />THE SURGE ARRESTORS DESCRIBED IN THIS MOP ARE TO BE MOUNTED ON THE <br />MOUNTING PLATE SOLD BY THE MANUFACTURER. THEY MAY BE GROUNDED IN ONE <br />OF THREE WAYS: <br />1. IF THE ARRESTOR MOUNTING PLATE IS MOUNTED ON THE TELCO BOARD AND <br />IF THE TELCO GROUND BAR IS BONDED TO THE EXTERNAL GROUND RING, THE <br />PLATE MAY BE BONDED TO THE TELCO GROUND BAR WITH A #2 AWG INSULATED <br />STRANDED COPPER WIRE AND SUITABLE COMPRESSIONOTYPE 2-HOLE LUGS. <br />2. IF THE ARRESTOR PLATE IS NOT MOUNTED ON THE TELCO BOARD. BOND IT <br />DIRECTLY TO THE EXTERNAL GROUND RING WITH A Q2 AWG SOLID TINNED <br />COPPER WIRE. USE A PVC CONDUIT THROUGH THE SHELTER WALL AT A 45 <br />DEGREE ANGLE TO ALLOW THE GROUND LEAD TO EXIT THE SHELTER FOR <br />BONDING TO THE EXTERNAL GROUND RING. <br />3. IF AN EXISTING #2 AWG GROUND CONDUCTOR EXISTS THE SHELTER (TO THE <br />EXTERNAL GROUND RING) WITHIN 2FT OF THE MOUNTING PLATE LOCATION, THE <br />PLATE MAY BE BONDED USING A 02 AWG INSULATED STRANDED CONDUCTOR WITH <br />A COMPRESSION TYPE 'C' TAP AND A SUITABLE COMPRESSION TYPE 2 HOLE LUG. <br />MAKE ALL CONNECTIONS TO THE ATS CASE, THE GENERATOR FRAME, THE <br />EXTERNAL FUEL TANK (IF PRESENT AND IF SUPPORTED BY THE MANUFACTURER) <br />AND THE SURGE ARRESTOR MOUNTING PLATE WITH SUABLE 2—HOLE <br />COPRESSION—TYPE LUG AAND STAINLESS —STEEL SCREWS, STAR —TYPE LOCK <br />WASHERS AND NUTS. REMOVE PAINT AT THE POINT WHERE THE COMPRESSION <br />LUG CON'AC'S THE MATING METAL SURFACE IN QUESTION TO ENSURE A GOOD <br />METAL—T-)—METAL CONTACT. APPLY ANTIOXIDANT TO THE MATING SURFACES. <br />ENSURE THAT ALL UNDERGROUND OR OUTDOOR CONNECTIONS TO A GROUNDING <br />SYSTEM ARE EXOTHERMICALLY WELDED (CAD —WELDED). <br />PERFORM AL'. GROUNDING WORK IN ACCORDANCE WITH STDS 2976175. <br />CONSTRUCTKM STANDARDS <br />ELECTRICAL NOTES <br />Together with NEXTEL <br />PACIFIC TELECOM SERVICES, <br />LLC <br />4072 <br />THOMAS R. HOLLAND <br />STATE OF WASHIN=TON , <br />1 � � <br />Q= <br />vj00x <br />w <br />E-1 <br />GROUNDING PLAN AND <br />ELECTRICAL NOTES <br />JOB / <br />DRAWING / <br />WAD41 <br />C-I <br />REVISION 1 0 <br />