My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3114 21ST ST 2018-01-02 MF Import
>
Address Records
>
21ST ST
>
3114
>
3114 21ST ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2021 8:14:21 AM
Creation date
4/2/2017 4:46:52 PM
Metadata
Fields
Template:
Address Document
Street Name
21ST ST
Street Number
3114
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENGINEERING / PUBLIC SERVICES DEPARTMENT <br />June 12, 2006 <br />Ms. Emily I-lukill <br />3114 - 2 1 " Street <br />Everett, WA 98201 <br />Subject: Project: <br />Job Address: <br />Plan Check No <br />Dear Ms. Hukill: <br />I-iukill <br />3114 - 21" Street <br />C0605-013 <br />In response to your application for a construction permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions or additions may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />2003 International Residential Code, as amended by the State of Washington and/or <br />Washington State Energy Code 2004 Edition, and adopted by the City of Everett, unless stated <br />otherwise. <br />In order for the processing of your application to continue, it will be <br />necessary to provide the Building Division with two complete new sets of <br />drawings reflecting the corrections requested. <br />1. Provide detail(s) showing how loads from the roof are transferred to existing 12" <br />diameter columns. <br />2. The floor plan does not match the site plan please clarify. <br />3. Show how cone at vehicle entrance is supported between 12" colunuts. <br />4. Provide 3" x 3" x 1/a" plate washer on all anchor bolts in braced wall lines. <br />5. Prescriptive compliance for braced wall panels requires a continuous footing with <br />anchor bolts within 12" of each end of each sill plate. Anchor bolts shall be <br />minimum of 7" embedment. <br />6. Show appliance protection in garage. As located, the appliances would require 2 <br />bollards. <br />7. Provide design for roof rafters and connection at ridge prepared by a li.:ensed <br />ishington State Structural Engineer. Also specify connection of rafters to plate at <br />r( ,f p +meter. <br />CITY OF -TT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 ��� <br />uruu1` +CXKen V. cuwsou pn4-2P'sq <br />
The URL can be used to link to this page
Your browser does not support the video tag.