My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10612 10TH DR SE 2016-01-01 MF Import
>
Address Records
>
10TH DR SE
>
10612
>
10612 10TH DR SE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2017 7:10:11 AM
Creation date
4/3/2017 7:10:06 AM
Metadata
Fields
Template:
Address Document
Street Name
10TH DR SE
Street Number
10612
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�w <br /> !/�,,.z �� I <br /> ci1�Y or rvr:aL11� <br /> BUILDING DEPARTDIGN'C <br /> PLAN CORRECTION SH�IiT <br /> ll�'l'L February 21 , 1984 USE <br /> OIiNER �Standard Pacific NW Corp USti ZONING <br /> CON';ItACPOP. Same _ FIRE ZONE _ <br /> ARCIIITECT OCCUPANCY GROUP <br /> J013 SI1'� AUllRESS Lot 25 Firever OCCUPANT LOAD <br /> TYPti OP CbNS1'P,UCTION PI.AN CFIECK N0. 84/12986 <br /> in response to your application for a permit , your plans an�l specificutions <br /> 1-�:ive Ueen examined and you are advised that the issuance of a permit is <br /> 1J7.t�l}lCl(1 for the reasons ]iereinafter set forth . NO'I'E CAREPULLY : Ans�ver <br /> questions and make explanatiens by correcting original. plans , end netia <br /> pla�is must be submitted to the Uuilding Inspect�on Department . (T11is sheet <br /> must be returned wit'� original plzns and specifications or thr,y will be <br /> filed as new business . l �i <br /> Itcm No. UNIPORM BUILDING CODH 1979 EDiTIOP: CODE SF:C . � <br /> �� . Under floor insulation to be supported to prevent sagging . Energy Code <br /> � ; Z. Calculated areas of ventilation for attic and enclosed <br /> rafter spaces inust be doubled to provide the net free area � <br /> thrnugh insect screen. Refer to Note 9 Sheet 11 . 22 x 3-1/2' � <br /> screened vents won't work because insulation aiill cover �' <br /> r <br /> most of it. Continuous screened vents will be required. 3205(c) <br /> � 3. All insulated ceilings, walls and floors must have a con- <br /> tinuous vapor barrier applied to tfie warm side. Ener9y Code <br /> �. �- <br /> y �: <br /> �' 4. It is not possible to provide R-11 insulation above cra4il � �: <br /> space vents through rim joists. Vents should go through �' � <br /> foundatien walls. � r' <br /> 5. Dottom of footings to be minimum 18" below finish grade. � <br /> � �'. <br /> ;/ 6. Provide means of venting joist spaces above and below the � F <br /> skylight. '� ' <br /> � � <br /> i 7 . 4" x 8" beam over archway betv+een DR & LR is overstressed � U <br /> in horizcntal shear. /� .: <br /> i � � oz <br /> < � „ <br /> Z F <br /> � ��", <br /> � / - .;, , � ; <br /> �ck Frets, P1 ns Examiner � <br /> � � ; <br /> G �: <br /> � :. <br /> I a s;c�—o f�— <br />� <br />
The URL can be used to link to this page
Your browser does not support the video tag.